10
CAUTIONS DURING OPERATION
1) When operating the pump for the first time with the pickup hose submerged in solution,set
the pressure control valve handle to the "Start" position,and allow free flow of air or water out of
spray gun or wand,to allow pump to prime with minimal resistance.
2) If the pump is operated without the pickup hose being submerged in solution it will cause
damage to the pump packing. Do not run the pump without liquid,except when draining,and
then for not more than 20 seconds.
3) When chemical is depleted,set the engine immediately to idle. This allows the clutch to dis-
engage the engine from the pump.
4) When the spraying condition is not satisfactory,increase the rpm of the engine,or remove
and clean the nozzle,and replace the orifice disk with a new disk if there are any signs of wear
or damage.
5) The equipment has a centrifugal clutch,therefore running at low rpm's will not allow the
clutch to completely expand and engage the drum. If the equipment is used with the clutch
not properly engaged,the clutch can be damaged.
6) When the engine is operated continuously at a low or medium speed for a long time car-
bon deposits will build up on top of the piston and in the exhaust port. Therefore,occasionally
run up to high speed to help remove carbon deposits. Removal of carbon should be per-
formed as regular maintenance.