POWER SUPPLY
CONNECTING YOUR MACHINE TO THE POWER SUPPLY: (240V ONLY)
To eliminate the possibility of an electric shock, your machine has been fitted with a BS
approved, rewireable moulded plug and cable which incorporates a fuse, the value of
which is indicated on the pin face of the plug. Should the fuse need to be replaced an
approved BS1362 fuse must be used of the same rating, marked thus .
If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the
cable should now be suitably prepared and the correct type of plug fitted. See below.
*WARNING:
A plug with bare flexible wires exposed is hazardous if engaged in a live power socket
outlet.
WARNING: THIS APPLIANCE IS DOUBLE INSULATED.
Blue - Neutral, Brown - Live.
As these colours may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured blue must be connected to the terminal which is marked
with the letter 'N' or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter 'L' or coloured red or brown.
EXTENSION LEAD CHART:
Extension lead sizes shown assure a voltage drop of not more than 5% at rated
load of tool.
3 6 10 13
Extension cable length Wire size mm
2
7.5m 0.75 0.75 1.0 1.25
15m 0.75 0.75 1.0 1.5
22.5m 0.75 0.75 1.0 1.5
30m 0.75 0.75 1.25 1.5
45m 0.75 1.25 1.5 2.5
Ampere rating
(on name plate)