Sunis™ RTS Light Sensor Programming/Operating/Installation Instructions
Page 3 of 4
STEP FOUR: OPERATION
The Sunis WireFree RTS Light Sensor cans be operated in either Demonstration Mode (temporary) or Standard (default) mode.
DEMONSTRATION MODE
Demonstration mode reduces the standard operating time delays, permitting almost
instantaneous operating/output response from the Sunis light sensor. This mode facilitates
initial light sensitivity (threshold) settings and quickly demonstrates the operation of the
motorized end product.
① Press and hold MODE BUTTON until LED indicator blinks (color red) LED will continue
to blink for approx. 30 seconds then extinguish (4ee Figure 5).
② If necessary, adjust sun sensitivity (threshold) setting (refer to STEP 3. [4 & 5]) LED will
blink during this mode. Should LED indicator extinguish prior to fi nal setting, simply
press the mode button momentarily to reactivate blinking LED indicator.
③ Sunis RTS light sensor will send a "DOWN" command to the RTS receiver or motor
after 5 seconds of sensing light within the set threshold.
④ Sunis RTS light sensor will send a "UP" command to the RTS receiver or motor IMMEDIATELY after sensing light that HAS NOT reached
(or below) the set threshold.
Note:
① Sunis light sensor will automatically default to standard operating mode after 3 minutes.
② *Rotating the Sun Sensitivity Selector to a FULL COUNTER CLOCKWISE (-) position will simulate sun if no sun is present. It is not
recommended to leave the selector (Threshold setting) in this position.
STANDARD OPERATING MODE
Standard operating mode (default) employs output response time delays.
1 Refer to STEP 3. [1-5] (Setting the Light (Sun) Sensitivity Threshold)
2 Sunis RTS light sensor will send a "DOWN" command to the RTS receiver or motor after 5 Minutes of sensing light within the
set threshold.
3 Sunis RTS light sensor will send a "UP" command to the RTS receiver or motor after 30 Minutes of sensing light that HAS NOT reached
(or below) the set threshold.
Note: LED indicator light will remain illuminated for approx. 15 seconds. To confi rm present light level, momentarily press the
mode button to illuminate the LED indicator light.
GREEN LED: INDICATES SUN (Light) WITHIN THRESHOLD SETTING
RED LED: INDICATES SUN (Light) BELOW THRESHOLD SETTING
Note: The Sunis WireFree RTS light sensor is capable of providing control in accordance to light level conditions only.
Once a command is sent, the Sunis will not send another command until there is a change in light condition.
Figure 5
Page 30 of 124