Operating instructions

Copyright © 2014 Draper Inc. Form ScissorLiftSLX_Inst14-R Printed in U.S.A.
Planning
Based on screen location and projector specifications, determine proper
position for projector installation.
Confirm that there is adequate space for installation and operation. Minimum
clearance above ceiling level varies according to Scissor Lift model, plus height
of projector, optional mounting bracket, optional ceiling closure, and optional
Environmental Air Space Housing.
Arrange to provide service access to the unit.
Maximum lifting capacity is 350 Lbs.
As Soon As Scissor Lift Arrives
Open carton and inspect for damage.
Locate the following parts:
A. The unit itself
B. Controls
C. Optional equipment: Environmental Air Space Housing, Universal
Projector Mount, closure panel or ceiling finish kit (all ship in separate
cartons).
Test lift prior to installation. Please Note: Packaging must be removed from
lift before testing.
Installation/Operating Instructions
Scissor Lift SLX Video Projector Lift by Draper
Electrical Connections
Unit operates on 115V AC, 60 Hz. current. 10.93 amps current draw (3.93 amps
for lift, 7 amps for outlet). Opening the electrical box exposes terminals for field
connections. Unit is shipped with internal wiring complete.Wire to connect unit
to power supply should be furnished by installer. Connections should be made
in accordance with wiring diagram, and wiring should comply with national and
local electrical codes. An appropriate disconnect device shall be provided as part
of the building installation. All operating switches should be “off before power is
connected.
If you encounter any difficulties installing or servicing your Scissor Lift SLX, call your
dealer or Draper, Inc. in Spiceland, Indiana, 765-987-7999, or fax 765-987-7142.
Operation
Before operating or testing the unit, make sure the
packaging has been removed from the unit. This can be
accomplished by removing the eight screws (four per side)
holding the packing frame to the lift. Once the packaging is
all removed, operate the lift in the "Up" direction, so the lift's
control encoder will recognize it's "home" location. Until you
do this, the Down function will not work.
When unit is first operated, be cautious! If unit fails
to operate properly, press “off” and recheck electrical
connections before proceeding. Cycle unit down and
up several times to confirm satisfactory operation. You
must also do this if the Scissor Lift ever loses or is
disconnected from the power.
Caution: Do not pull on or touch safety belt when unit
is in motion. If belt locks, the cables will unspool.
Caution: Obstructing bottom pan may cause cables
to unspool.
Standard Single Station Low Voltage Control (See Fig.
1)—One three-button switch with “Up”, “Down”, and “Off
buttons. Lift starts up or down when appropriate button
is pressed, and may be stopped by pressing “Off button.
Factory set limit switches stop lift automatically when
projector is in “show” position. One momentary key switch lowers lift from “Show”
to “Service” position.
Optional Multiple Station Control—Optional, moves lift from “Stored” to “Show”
position only. Each switching station has a three-button switch with “Up”, “Down”,
and “Off” buttons. Lift starts up or down when appropriate button is pressed,
and may be stopped by pressing “Off button. Factory set limit switches stop lift
automatically when projector is in “Show” position.
Optional Key Operated Switch—If ordered, the standard LVC-S can be replaced
with a second single station, momentary key-operated three position (up/off/down)
switch. Multiple Station Control required for this option. Moves lift from “stored” to
“show” position only.
Optional Infrared or Radio Frequency Remote Control—If ordered, a three-
button transmitter is provided, with “up”, “down”, and “stop” buttons. Unit starts up
or down when appropriate button is pressed, and may be stopped by pressing
“off” button. Factory set limit switches stop unit automatically when projector is in
“show” position. Only controls "show" and "stored" positions.
Optional RS232 Control—For Serial communication an R2D7 Serial
Communications Interface is optionally available.
Low Voltage Trigger—Input provided for Low Voltage
Trigger from projector (see diagram on page 4).
Please Note: Scissor Lift SLX must be installed in accordance with the
requirements of the Local Building Codes, the Canadian Electrical Code (CEC),
CAN/CSA C22.1 and the National Electric Code (NEC), NFPA 70, as required. An
appropriate disconnect device shall be provided as part of the building installation.
Caution:
IMPORTANT SAFETY INSTRUCTIONS
Read all instructions completely before proceeding.
DANGER: To reduce risk of shock:
Always disconnect power from lift before cleaning.
WARNING–To reduce risk of burns, fires, electric shock or injuries to persons:
Disconnect power from lift before putting on or taking off parts.
Use this lift only for its intended use as described in these instructions. Do
not use attachments not recommended by the manufacturer.
Never operate this lift if it has a damaged cord or plug. If it is not working
properly, call your dealer or the manufacturer for assistance/repair.
Keep cords away from heated surfaces.
Never operate lift with air opening blocked. Keep the air openings free of lint,
hair, and the like.
Never drop or insert any object into any opening.
Do not use outdoors.
Route cords and cables as shown in the instructions.
WARNING: Rick of Electric Shock—connect this product to a
properly grounded electrical supply.
IMPORTANT INSTALLATION/OPERATING INSTRUCTIONS
WARNING: To prevent injury, this apparatus must be securely attached to
the building structure in accordance with the instructions.
Test lift prior to installation. Please Note: Packaging must be removed from
lift before testing.
Follow instructions carefully. Installation contrary to instructions invalidates
warranty.
Do not obstruct operation of Scissor Lift SLX with fingers or any object.
Serious injury or damage could result.
Lift is intended for use with product weighing not more than 350 pounds.
Scissor Lift SLX is designed to accommodate ceiling suspended equipment.
Equipment should not be allowed to rest on optional ceiling closure
during operation (refer to section titled “Installing Projector”).
Entire bottom of unit must be unobstructed to permit proper operation.
Sufficient clearance must be allowed below projector or optional ceiling closure:
10' for Model SLX10, 14' for Model SLX14, etc
.
Unit must be installed level (use a carpenter’s level).
Unit operates on 115V AC 60 Hz. current. 10.93 amps current draw (3.93
amps for lift, 7 amps for outlet).
Verify the show position when testing lift. Make required changes by referring
to adjustment instructions on page 4 of this document.
The maintenance/service factory limit setting must not be adjusted to a lower
position than the preset factory limit setting. In addition, Draper does not
recommend setting show position at the maintenance/service position—for
example, if you wish to have 8' show position, order a lift with at least a 10'
maintenance position.
 When the Scissor Lift SLX is to be installed in “other space used for
environmental air” the optional environmental air space housing must
be installed per instructions to isolate the lift from the “other space
used for environmental air.
 When Scissor Lift SLX is NOT installed in environmental air space housing
and optional ceiling closure, the ALTERNATE wiring for up limit switch may
be used (see Alternate Wiring schematic on page 5).
CAUTION: Before servicing unit, disconnect hardwired control and any
remote control.
Note: Unit has been thoroughly inspected and tested at factory and found to be
operating properly prior to shipment.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK. DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR.
Scissor Lift SLX is approved to UL 2442 and CSA C22.2 No. 60065-03.
Caution:
Beware
of pinch
points
D C U
2¾"
4½"
7
/8"
Front Side Back
LVC-S
Up & Show
UP
OFF
DOWN
UP
DOWN
OFF
SP-KSM
Service
Figure 1
Caution: Make sure electrical supply has been disconnected before
attempting to connect Scissor Lift to electricity.
Scissor Lift should be operated and checked prior to installing projector and/or
optional ceiling closure.
Low Voltage Control Switch shown below comes with 75' of non-plenum rated
cable and should be plugged in to Control Panel on top frame of lift for control
of the "Up" and "Show" positions. Momentary Key Switch shown below comes
with 75' of cable and should be plugged in to Control Panel on top frame of lift for
control of the "Service" position.

Summary of content (7 pages)