Safety Instructions

OPERATION GUIDE
Motor P1 button operation
Note: After the success of the reversing,retain all motor original settings.
Note:After the Reset to factor mode,will delete all previous system function setting and the emitter code.
2, Paring / Pair additional emitter / Remove one emitter
Enter paring status
Repeat paring operation
Loosen P1
Run for hint x1
4, Switch direction
5, Restore factory setting
Press 2s
Successful change the direction
Loosen P1
Run for hint x3
Press 10s
Restore factory setting successfull
Loosen P1
Run for hint x4
Press 14s
1, Short press function
Short press
P1
Motor run upward / stoprunning / run downward ……
“Di~” x1
“Di” x3
“Di” x4
Note: This operation should be carried out under the conditions of motor has the limit.
Note: in the factory mode, enter paring status; In the user mode, enter pair additional emitter or remove one emitter.
Press 1s
P2
The motor running
speed is improved
6 Speed Regulation
Press 1s
Run for hint x2
Press 1s
The motor running
speed is reduced
P2Up/DownUp/Down
Run for
hint x1
“Di” x1
Run for hint x1
“Di” x1
Press 1s
Run for hint x2
Press 1s
Run for hint x1
“Di” x1
Note: When the motor enters the radio lock mode, all the setting memory will be saved, only the radio receiving
function has been disabled.
3, Radio lock mode
The motor enters Radio Lock mode
Loosen P1
Run for hint x2
Press 6s
“Di” x2
Note: If the motor no response, it has already been the Max. or Min speed; The continuous motor speed has 3 grades,
20r/min, 24r/min, 28r/min, and the factory default is the fastest speed.
Fault and solution
1
ISSUE SOLUTION
The motor
doesn't run
NUMBER
a, Activate the motor afterfully charged
b, Paring again;
c, Contact after sales service
for more details
POSSIBLE CAUSES
a, The battery is not activated.
b, The emitter hasn't been paired;
c, If press P1 button for long time,
the motor no reaction, probably
the board is short circuit, or the
motor is broken.
Tubular Motor-
DM28LEU/S
Specification
(A-02)
P2StopStop
3rd limit
position
is ok
Press 1s Press 1s
Press 1s
Press 1s
Press 1s
P2
2 3rd preferred stop position setting
2.1, Set the
3rd limit position
The 3rd limit position setting : If you have already set the upper and lower limit, then you can set the
3rd limit between upper and lower limit.
Run for hint x1
“Di” x1
Run for hint x1
“Di” x1
Run for hint x2
“Di” x3
Up+DownStop
Note: when under jog mode, press up/down button once, the motor will be jog running, if press more than 2S, the motor
will be continously running.
Press 5s Press 1s
Run for hint x1
+
1 Jog mode & running mode switch
Run for hint x2
“Di” x3
Run for hint x1
T<10s
Loosen P1
Paring is OK
Press 2s
Press 2s
Press 1s
Press 2s
+
Run for hint x1
The curtain
run downward
2 Switch rotating direction(optional)
Successfully switch direction
Upper
limit is OK
Press 2s
3.1, Setting the upper limit
3 Setting upper and lower limit
The curtain
run upward
Press 2s
3.2, Setting the lower limit
The curtain
run downward
The curtain
stops running
The curtain
stops running
User mode
UpStopUp+Stop
DownStopStop+Down
Run for hint x2
“Di” x3
Press 2s
+
Lower
limit is OK
Run for hint x2
“Di” x3
Press 2s
+
Stop
1 Paring
Factory mode
UpUp+Down
Note: In the user mode, power on the code can also operate;If 10s,no stay setting up emitter preess or no legal stop
button code,10s to the limit,will automatically exit the setting up mode.
If you need to reverse the rotateon of the motor controlled by the emitter,pls switch channel address.
Note: After the success of the reversing,retain all motor original settings.
Switch to jog mode
Switch to running mode
Run for
hint x1
“Di~” x1
Run for
hint x2
“Di” x3
“Di~” x1
The upper
limit
Run to the desired
upper position
Run to the desired
lower position
The lower
limit
Run to the req-
uired preferred
stop position
preferred stop
position
(Any position)
Run for
hint x1
T<10s
Loosen P1
Press 2s Press 2s
Loosen P1
Press 2s Press 2s
2.3, Clear the 3rd limit position
P2StopStop
2.2, Run to
the 3rd limit position
The motor runs automatically to
the 3rd limit position
Stop
Run for hint x1
“Di” x1
Run forhint x1
“Di~” x1
Clear
the 3rd limit position
is ok
Run for hint x1
“Di” x1
Run for hint x1
“Di” x1
Run for hint x2
“Di” x3
Run for hint x1
“Di” x1
Run for hint x1
“Di” x1
Run for hint x2
“Di” x3
Run for hint x2
“Di” x3
Run for hint x1
“Di” x1
Press 1sPress 1s
Press 2s
Press 1s
Press 1sPress 1sPress 1s
Press 2sPress 1sPress 1s
P2
P2 P2
P2
New emitter is paired to the motor
Run for hint x2
“Di” x3
Adjust the
required upper
limit position
Adjust the
required lower
limit position
+
The new
upper
limit is OK
or
or
Press 1s Press 2s
4 Pair additional emitter
3 Adjust limits
Method three
New emitter is paired to the motor
Method one
Run for hint x1
“Di” x1
Run for hint x2
“Di” x3
Run for hint x1
“Di” x1
Press 1sPress 1sPress 1s
Method one
P2 P2 P2
P2 P2
New emitter is paired to the motor
Method two
Method one
Method two
P2 P2 Stop
Up+StopUp/DownUp+Stop
Down+StopUp/DownDown+Stop
3.1, Adjusting the upper limit position
3.2, Adjusting the lower limit position
Press 5s
+
Run forhint x1
“Di~” x1
Run for hint x2
“Di” x3
Run forhint x1
“Di~” x1
Enter to
the process
of adjusting
the limit
+
The new
lower
limit is OK
Press 1s Press 2s
Press 5s
+
Enter to
the process
of adjusting
the limit
Stop
Note: After entering the limit fine-tuning mode, the original
3rd limit position
will not be deleted;If there is no
button operation in 2 minutes, 2 minutes time limit, motor chance to rotate the hint, and automatically exit the limit
fine-tuning mode;After fine-tuning the up/down limits can not be in the same position.
Run for hint x1 “Di~” x1
Run for hint x2
“Di” x3
Method two
Stop
Run for hint x1 “Di~” x1
P2 P2
P2
One emitter have been removed
5 Remove one emitter
P2 P2 P2
One emitter have been removed
Note: Emitter is the paired emitter for master motor, is unpairing emitter; After the emitter is added, keep all
the original settings of the motor.
Note: are all of the code emitters,this method only can delete the emitter not the emitter ;After deleting
the emitter, keep all the settings of the motor (the limit is reserved for the previous setting).
Power on to 1Power off to 0
1
0
1
0
During the limit setting mode, press UP/DOWN once, the motor will jog running, if you press UP/DOWN 2S,
the motor will run continuously.
Successfully switch direction
Loosen P1
Run for hint x3
Press 10s
“Di” x3