DF330 OPERATOR’S MANUAL
4
POWER CONNECTION
The unit will have been supplied with a power cable suitable for domestic power outlets
in your country. For your own safety it is important that you use this cable. The unit
should always be connected to the mains supply earth using this cable.
If for some reason the unit is to be used at a mains input operating voltage which is
different to that as supplied, the following procedure must be carried out.
1: Disconnect the unit from the mains.
2: Using a number 1 size pozidrive screwdriver, remove the two self-tapping
screws holding the voltage selection switch cover plate on the rear panel.
3: Remove the cover plate and slide the switch fully to its opposite end.
4: Rotate the cover plate one half turn, (180E) and refit the two screws.
5: Replace with a correctly rated fuse for the selected operation voltage.
6: Re-connect to mains power source.