Installation Guide   LP20RF & DIGISTAT+RF
CLOCK?
6:30
10:30
OFF
Before fixing the Digistat+RF to the wall it is recommended 
to first check the signal strength from that location.
To do this, after initial start up, the colon, CH and antenna 
symbols should be ashing on the LP20RF display.
1.
Press the set? button 4 times. 
2.
Press the OK button once. 
3.
Press the set? button 4 times; Lrn and OFF should 
be displayed. 
4.
Press the + button so the display shows ON and a 
ashing antenna symbol. The learn mode is now 
ready to receive a signal from the transmitter 
during the next two minutes. 
5.
Take the Digistat+RF unit and stand near the boiler. 
6.
Remove the battery cover and t the batteries. 
7.
The symbols on the receiver will stop ashing and 
the display will show ‘SSI, Antenna and ON’. 
8.
Press ‘SET’ on the receiver and the display will
show ‘SSI and Antenna’. 
CLOCK?
6:30
10:30
OFF
CLOCK?
6:30
10:30
OFF
CLOCK?
6:30
10:30
OFF
9.
After a few seconds the display will show ‘- - -’. 
Remove the batteries from the Digistat+RF, press 
and hold the ‘set’ button whilst retting the 
batteries, keep the ‘set’ button held and after a few
seconds the display will show ‘rF’ which indicates 
that the Digistat+RF is continuously sending a 
signal to the LP20RF (receiver). 
The receiver display will now show the ‘learnt’ 
transmitter code and the antenna’ as well as the 
signal strength as indicated by the chevrons on the
right hand side of the display.
J 
Place the transmitter in the desired nal position
and return to the boiler to check the receiver 
display. The ideal transmitter position will result 
in the receiver display showing 4 chevrons and the 
LED will be green. 
K 
If the LED is red or no LED is showing and the
display indicates 1 or 2 chevrons, the transmitter 
will need to be re-positioned until the LED 
changes to amber or green and 3 or 4 chevrons are 
indicated on the display.
 NOTE: 
If there is no LED and the display shows ‘- - -’, there 
is no signal being received at all from the transmitter. 
Transmission will resume once the transmitter is re-
positioned in a part of the house where an amber or 
green LED and 3 or 4 chevrons are achieved.
L 
Once you are happy that, when in the desired 
location, the transmitter is sending a good signal 
to the receiver i.e. amber or green and 3 or 4 
chevrons, the transmitter can be xed to the wall.
CLOCK?
6:30
10:30
OFF
LED Indication Chevrons  RF Strength
Green 4 Very strong
Amber 3 Strong
Red 2 Weak
None 1 Very weak
Signal strength 
indicators
Transmitter code
(may be different)
LED indicator shows different colour depending
on signal strength (see table below)
Wireless Commissioning 
& Signal Strength
5LP 20R F & DI GI STAT+R F
06515085001 ISSB