Installation Guide

©2017 DreamLine. All Rights Reserved
INFINITY-Z manual Ver 4 Rev 5 06/2017 10
Fig 11
Fig 10
1 2
3
4
5
Ø5/16"
Outside
NOTE: Towel Bar must be installed on the outside of the Stationary Glass.
!
11. Attach the Towel Bar (#18) to the outside of the Stationary Glass (#05). (Fig 11)
10. Use a helper to hold the assembly in position and mark the drill holes on the wall through the
holes on the flange of the Wall Profiles (#02).
Gently set the assembled unit aside; drill the holes using a Ø5/16” drill bit and insert the Wall
Anchors (#14).
Apply silicone along the Wall Profile (#02) and around the holes on the wall. Also apply silicone
caulk under the Bottom Guide Rail (#03). Place the entire shower assembly back into the designated
position and secure it to the walls using the Truss Head Screws ST4.2×40 (#09). (Fig 10)