Manual

© DreamLine
All Rights Reserved
© DreamLine
All Rights Reserved
Installation steps for 6” hinge panel with Hinge Panel Glass Bracket
10
UNIDOOR-X (STYLE M) manual Ver 2 Rev 1 02/2019
©2019 DreamLine. All Rights Reserved
!
NOTE: Refer to the
enclosure panel
manual for the
correct dimensions
for enclosure
installations
Plumb line
Out-of-plumb
at the bottom
<Less than 90°
A
Plumb line
**If the wall is
out-of-plumb at the
bottom, measure that
dimension (A) and add
it to the length of the
U-channel (1/4” max):
Finished cut length=
Glass Width + 3/16”
+ dimension A
Vertical
U-channel
Hinge Panel
Glass Bracket
1-9/16”
69-7/16”
6”
Bottom
U-channel**
Fig 2
Carpenter’s
Square
Model
height
of 72”
Fig 1
1. Draw a line on the threshold and up the
wall to represent the outside edge of the
U-channels. Make sure the line is parallel to
the front edge of the threshold. (Fig 1)
2. Use a hacksaw or a miter saw:
Cut the Vertical U-channel to 69-7/16”.
Cut the Bottom U-channel** to 6”. (Fig 2)