ENIGMA-XO SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine® reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.
This model is treated with DreamLine’s exclusive ClearMaxTM Glass technology. This is a specially formulated coating that prevents the build up of soap and water spots. Install the surface with the ClearMaxTM label towards the inside of the shower. Please note that depending on the model, the glass may be coated on either one or both surfaces. ©2017 DreamLine. All Rights Reserved For best results, squeegee the glass after each use and dry with a soft cloth.
Table of Contents Section title Page # Model Information Reinforcement Information 5 6 Preparation Tools 7 Parts List 9-10 Installation Vinyl Seals Stoppers 11- 29 25 SafeStop™ Bumper 27-28 Wheel Adjustments 30 Product maintenance 31 8 ©2017 DreamLine.
NOTE: This manual will describe the installation of the single threshold model of the Enigma-XO). For the ENIGMA-XO Enclosure installation, please use the manual that is packaged with the return panel glass. ENIGMA-XO ENCLOSURE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS IMPORTANT DreamLine® reserves the right to alter, modify or redesign products at any time without prior notice.
A B B C A E ! IMPORTANT INFORMATION REGARDING THE INSTALLATION OF THIS SHOWER DOOR D PANEL DOOR F A B C Guide Rail Brackets must be firmly attached to the wall. Installation into a stud is strongly recommended. All of the guide rail bracket set screws must be tightened. Thread Lock must be applied to both stopper set screws. Panel-side stopper must be installed into the pre-drilled stopper hole in the upper guide rail.
Reinforcement for Enigma Series Heavy Glass frameless sliding shower door Install studs OR install 2”x 6” wood blocking between the studs where the Guide Rail Brackets will attach to the wall d Stu or 2” ” X6 2” ” X6 measured from threshold* (see list below) ©2017 DreamLine.
Preparation 1. After opening all boxes and packages, read this introduction carefully. Check that all of the needed parts are included in the package by marking all the components on the “Detailed Diagram of Shower Door Components”. Examine boxes and packages for shipping damage. If the unit has been damaged, has a finishing defect, or is missing parts, please contact our customer support department within 3 business days of the delivery date.
Tools Tape Measure Level Drill bit (Ø=1/8") (3mm) Drill bit (Ø=1/4") (6mm) Razor Knife Painter’s Tape Phillips Screwdriver Pencil Drill bit (Ø=5/16") (8mm) Drill bit (Ø=3/8") (10mm) Hammer Professional-grade Glass suction cup Silicone Power Drill Chop saw or Hacksaw Tip: Measure the finished opening before proceeding with the installation to be sure that the correct model size has been ordered. ©2017 DreamLine.
Detailed Diagram ‘A’of Shower Door Components 11 10 12 13 9a/9b 8 7 1 2 4 3 14 15 5 16 17 6 18 The glass surface with the ClearMax™ label must be installed to face inside of the shower 19 30 model #s SHDR-61606220-## SHDR-61487620-## SHDR-61607620-## Packing List A PART# DESCRIPTION QTY PART# DESCRIPTION QTY 01 Door stopper 2pcs 12 Guide block (with caps) 1pc 02 Stationary glass 1pc 13 Bumper strip 1pc 03 Upper guide rail (for 48" or 60") 1pc 14 Anti-water strip 2pcs
Detailed Diagram ‘B’ of Shower Door Components (for 72” model width only) 24 14 18 23 19 21 The glass surface with the ClearMax™ label must be installed to face inside of the shower 22 9 model #s (for 72” ) SHDR-61727620-## 25 Packing List B DESCRIPTION QTY PART# 9b Wall anchor Ø5/16"(8mm) 2pcs 11 Allen Wrench 3,4,5 mm 14 DESCRIPTION QTY 21 Small stationary glass bracket 1pc 1set 22 Small stationary glass Bottom bracket 1pc Anti-water strip 1pc 23 Small stationary glass 1pc
Installation steps 1. Measure the distance between the two finished walls at the top, middle and bottom. This distance is marked as “W”. Also, check the threshold for level and the walls for plumb. (Fig 1) Top Note: The minimum threshold requirement for the ENIGMA-XO is 2-3/4” of flat threshold space. Middle Bottom 2-3/4” minimum W Fig 1 2. The Upper Guide Rail (#03) has been pre-cut for the model width of: 48”, 60” or 72”. (Note: The actual rail is shorter than the model width by design).
3a. Attach the Upper Guide Rail (#03) to the Stationary Glass (#02) 1 2 panel end with the Glass Brackets (#07) and tighten the bolts into the holes in the Upper Guide Rail (#03). Make sure both adjustment disks are installed in the same direction with the high spot towards the door end. (see *Note below) Make sure that the guide rail is attached parallel with the top edge of the stationary panel glass. 3b. Slide the Door Stoppers (#01) onto each end of the Upper Guide Rail (#03).
ATTENTION: This step shows the Small Stationary Glass Bracket (#21) installation for the 72” model only (not included with the 48“ or 60” model). 4. If the model width is 72” and includes the Small Stationary Glass (#23), attach the Small Stationary Glass Bracket (#21) to the Upper Guide Rail for 72” (#24) between the Door Stopper (#01) and the Guide Rail Bracket (#08) as shown in Fig. 5. 1 This bracket will be repositioned during the installation of the Small Stationary Glass (#23).
6. Place the Stationary Glass (#02) with the Upper Guide Rail (#03) onto the threshold and position it against the wall. (Note that the Stationary Glass (#02) installs to the outside of the Upper Guide Rail (#03)) Make sure the Stationary Glass (#02) and the Upper Guide Rail (#03) are level. If a horizontal adjustment is required; loosen, rotate and re-tighten the disks on the Glass Brackets (#07). (Fig 7) ©2017 DreamLine.
ATTENTION: This step shows the Small Stationary Glass (#23) installation for the 72” model only (not included with the 60” model). rotate disk(s) to level rail 7. If installing the 72” model: Fig 8a 1 2 3 4 ©2017 DreamLine. All Rights Reserved Unscrew the disk from the Small Stationary Glass Bracket (#21) and loosen the set screw that secures the bracket to the Guide Rail.
8. Once the Upper Guide Rail (#03) is level, mark the position of the Wall Bracket (#19) and Guide Rail Brackets (#08) on the wall. *NOTE: If installing the 72” model, also mark the position of the Wall Bracket (#19) on the opposite wall for the Small Stationary Panel Glass (#23) (see Fig 9.4*). (Fig 9) 1 2 3 4* for 72” model inside inside Fig 9 9. Make sure that the Stationary Glass (#02) is parallel to the front edge of the threshold and mark it.
10. After marking the positions of all the hardware, set the Stationary Glass (#02) with the Upper Guide Rail (#03) aside. 1 2 3 4* (If installing the 72” model, also remove the Small Stationary Panel Glass (#23) from the Upper Guide Rail (#03)). Remove the Guide Rail Brackets (#08) from the Upper Guide Rail (#03) and the Wall Bracket (#19) from the Stationary Glass (#02). Place the Wall Bracket (#19) and Guide Rail Brackets (#08) back to the outlined positions and mark the holes for drilling.
12. Fasten the Wall Bracket (#19) to the wall using the ST4.2×55 Truss Head Screw (#18). (Fig 13.1) If installing the 72” model, repeat this step to install the Wall Bracket (#19) for the Small Stationary Panel Glass (#23) (Fig 13.4). Install the base parts of the Guide Rail Brackets (#08) onto both walls using the ST6×55 Large Truss Head Screw (#10). Note that the adjustment set screws must be aligned vertically for easier access to adjust for level if necessary after the glass is installed.
13b. If installing the 72” model, repeat Step #13a for the Small Stationary Glass Bottom Bracket (#22). Loosen the set screw and remove the Guide Block Face Plate. 1 use a pencil or a center-punch to mark the hole 2 *NOTE: *see note ◾For installation into an Acrylic Threshold: drill an Ø1/8”(3mm) hole and use the ST4.2 x 40mm Countersunk Screw (#17) OR ◾For installation into a Tile Threshold: drill a Ø5/16”(8mm) hole and use the ST4.
14. Re-position the Stationary Glass (#02) and Upper Guide Rail (#03) onto the threshold and fasten both sleeves of the Guide Rail Brackets (#08) to the brackets on the walls. Tighten the set screws on the Guide Rail Brackets (#08) to secure the Upper Guide Rail (#03). Position the bracket set screws so that they are accessible from the top and bottom (Fig 15.1 and 15.2). Assemble the Wall Bracket (#19) at the bottom corner of the Stationary Glass (#02).
15a. For the 48”or 60“ model size: Measure the distance from the edge of the Guide Block (#12) to the wall. This distance will be “X”. Use a miter saw or a hacksaw to cut the Anti-Splash Guard (#15) to the size of: (X) + 3/8”. (Fig 15a) 15b. For the 72” model size: Measure the distance between the edge of the Guide Block (#12) to the Small Stationary Glass Bottom Bracket (#22). This distance will be “L”. Use a miter saw or a hacksaw to cut the Anti-Splash Guard (#15) to the size of: (L) + 3/4”.
17. Secure the Anti-Splash Guard (#15) to the threshold with several pieces of painter’s tape to hold it in position and tight to the threshold until the silicone fully cures. (Fig 17) Fig 17 18. Attach the Guide block face plate to the installed face plate ENIGMA-XO manual Ver 1 08/2017 ©2017 DreamLine. All Rights Reserved Guide Block (#12) and tighten the set screw with the supplied allen wrench. Use the supplied Decorative caps to cover the screw holes.
19. If installing the 72” model: attach the Small Stationary Panel Glass (#23) to the Upper Guide Rail (#03) using the Small Stationary Glass Bracket (#21). Attach the face plate to the Wall Bracket (#19) on the threshold (see Fig 19.5). (Fig 19) 1 2 3 4 5 outside Fig 19 20. If installing the 72” model: Attach the Guide block face plate to the installed Small Stationary Glass Bottom Bracket (#22) and tighten the set screw with the supplied allen wrench.
! NOTE: DO NOT attach the handle to the door glass until instructed to do so. DO NOT attempt to lift the door glass with the handle as this may result in damage to the glass and/or serious personal injury. 1 2 safety set screw 21. Attach two of the Rollers (#04) into the top holes on the Door Glass (#05) with the wheels facing outside of the shower. Apply Thread Lock Adhesive (#26) to the bolts and safety set screws.
! NOTE: The Safety set screw on both wheels MUST BE re-tightened after installation to prevent the large bolt from coming loose. Apply thread lock during installation. (See details Fig 23 and also on Page 28) add threadlock to the safety set screw and wheel bolt Fig 23 of the Stationary Glass (#02) and the Door Glass (#05) (Fig 24.1). Press the Bumper Strip (#13) onto the vertical edge of the Door Glass (#05) (48” and 60“ model). (Fig 24.
! 24. Position the Door Stoppers (#01) and screw them tightly to the Upper Guide Rail (#03). NOTE: The Door Stoppers (#01) must be positioned correctly to prevent the handle from contacting the Stationary Glass (#02) (48”, 60” & 72“ models) and to stop the Door Glass (#05) in a position that allows the bumper strip to create a seal with the wall, but does not allow the door glass to bang into the wall during normal operation (48” & 60” models).
25. Install the Bumper (#30) with the 3M tape: postion the Bumper (#30) onto the threshold and against the wall on the stationary panel side of the installation. (For 72” model, this will be the side of the opening with the large stationary panel). Remove the 3M Tape backing and position the Bumper (#30) onto the threshold against the Wall Bracket (#19). (Fig 25) NOTE: The surfaces need to be clean and free of construction debris before installing the bumper.
26. To install the Bumper (#30) with the screw method, position the bumper (#30) onto the threshold and against the wall on the stationary panel side of the installation. (For 72” model, this will be the side of the opening with the large stationary panel). and mark the position of the hole onto the wall. Drill a 5/16” hole and insert the anchor (###). Remove the 3M Tape and position the Bumper (#30) onto the threshold against the Wall Bracket (#19) and attach using the ST4.2 x 40 Countersunk screw.
27. Apply a good quality mildew-resistant silicone along the interior perimeter where the glass meets the wall and threshold and also along the Anti-Splash Guard (#15). (Fig 26) Please allow 24 hours for the silicone to fully cure before using the shower. 24 Hours ! ENIGMA-XO manual Ver 1 08/2017 ©2017 DreamLine. All Rights Reserved Fig 27 Do Not hang or drape a towel or wash cloth over the guide rail as this may cause the roller wheels to get stuck and possibly cause serious damage or injury.
Roller adjustment procedure for Enigma, Enigma-X and Enigma-XO To achieve minimal clearance beneath the door glass without making contact with the bottom guide block and creating a good seal with the wall. Have at least two 3/16” shims or wedge shims (to maintain space beneath the door glass) and an assistant available to help with this procedure. Adjust only one wheel at a time and you may need to perform these steps more than once to get the desired results.
Product Maintenance BASES and BACKWALLS: To ensure long lasting life for your acrylic back walls: wipe them off after each use with a soft cloth. To clean the acrylic back walls use non-abrasive sprays or cream based cleaners. Avoid the use of aerosol spray cleaners. Never use abrasive cleansers, metal brushes or scrapers that could scratch or dull the surface. GLASS: To ensure long lasting life for your glass shower products: wipe them off after each use with a soft cloth.
TEL: 866-731-2244 FAX: 866-857-3638 DREAMLINE.COM For more information on DreamLine® Shower Doors and Enclosures please visit DreamLine.com ©2017 DreamLine.