U-Channel
reference
mark
Fig 4
Fig 5
**NOTE: When installing to
a stud, drill a Ø1/4” hole and
do not use the anchors.
or Ø5/16"
Ø1/4"
2**
1
4
5
3**
4. Align the edge of the U-Channel (for Panel Glass) (#01)
to the inside of the reference mark on the threshold. Use a
level to hold the U-channel plumb and mark the position of
the U-Channel (for Panel Glass) (#01) on the wall.
Also mark the four holes for drilling through the pre-drilled
holes in the U-channel. (Fig 4)
5. Remove the U-Channel (for Panel Glass) (#01) from the wall, drill the anchor holes using a Ø5/16”
drill bit and insert the Ø5/16” Plastic Wall Anchors (#16) (**see Note below).
Apply a bead of silicone to the back of the U-Channel (for Panel Glass) (#01) and attach it to the wall
using four of the ST4.2 x 40 Round Head Screws (#17). (Fig 5)