Installation Guide

17ENIGMA SKY shower and tub door manual Ver 1 Rev 1 02/2018
©2018 DreamLine. All Rights Reserved
Fig 17
Fig 18
!
1-1/4”
measure 1-1/4”
from the plumb
line to the edge
of the bracket
inside the
shower
with the guide
rail level, mark
the bottom
position of the
bracket on the
wall
1
-
1
/
4
1
2
NOTE: It is important that
the guide rail is level when
marking the position of the
Guide Rail bracket on the wall.
To lower the rail:
Loosen the top set screw and
tighten the bottom set screw.
To raise the rail:
Loosen the bottom set screw
and tighten the top set screw.
1-1/4”
18. Using the reference mark on the threshold from Step #3,
draw a plumb line up the wall on the door side of the
opening. Measure over 1-1/4” into the shower from this line.
With the Guide Rail (#04) level, mark the position of the
Guide Rail Bracket (#06) on the wall. (Fig 18)
17. Level the Guide Rail (#04) across the opening.
If necessary, use the set screws on the Guide Rail Bracket (#06)
to adjust the level of the Guide Rail (#04).
(Fig 17 and Fig 18)