Installation Guide

UNIDOOR PLUS (Style-J) manual Ver 1 Rev 7 102016
12
8. Slip the U-channel 2 (44, bottom profile) (29)
onto the Stationary glass (11) and ensure that the
straight end of the U-channel 2 is flush with the
vertical glass edge.
Carefully butt the Stationary glass and Return panel
glass (26) together while on top of the half wall
ledge to form a tight corner from bottom to top. The
Stationary glass will be in front of the Return panel
glass.
While securely holding the two glass panels, attach
the 90° Corner Bracket (30) to the top corner.
Ensure that the 90° Corner Bracket is square and
gaskets are aligned properly before tightening the
glass holding screws.
Temporarily secure the bottom corner of the glass
panels with a generous strip of Painters tape.
Carefully butt the Return panel glass (26) up against
the wall vertically according to the M value stated in
Size Table B on page 5 and square it up with a level.
See Fig. 9 & 10 for details.
1
3
2
5
W1
4
Return glass
Stationary glass
outside
inside
Return
glass
Stationary
glass
outside
inside
outside
Painters tape
inside
M
outside
Fig. 9
1
3
5
2
4
NOTE: Steps #8 and #9 involve careful
handling of the glass panels to
determine a custom fit measurement
unique to your installation. It is
essential that two installers be used
along with responsive communication
once the panels are temporarily fixed
together.
6
Fig. 10
©2017 DreamLine. All Rights Reserved