Microprocessor Control
1. Power light indicates there is power on.
2. After initializing, dri Air will be displayed.
3. Press
START to start the dryer.
4. To set the temperature:
press SET - right display shows set temp
change setting using arrow keys
press ENTER to input new setting
5. Left display indicates actual temperature
6. Right display shows dewpoint or set temp
press TEMP D.POINT button to change
7. To set high temp alarm: (degrees over setting)
press ALARM - right display shows setting
change setting using arrow keys
press ENTER to input new setting
8. Status block indicates heater on or fault
9. See manual for setting 7-day timer .
10. Configuration of the dryer parameters is done
using the setup button. See manual.