Troubleshooting guide

Page 14
DRI-AIR INDUSTRIES, INC.
OPERATING MANUAL - ARID-X10B FLOOR MOUNT DRYER
Revision 3/28/02
Emergency Shutdown
In the event that a condition should arise that
requires the operator to immediately halt the
dryers operation, the operator can press the
rocker switch to the off position and the unit will
shut down completely. Remove the power plug
from the facilty outlet to cut all power from the
dryer.
Hopper Maintenance
1. Always clean hopper interior, air inlet port
and diffuser basket prior to adding or
changing materials.
2. Never over-fill the hopper. Material should
not obstruct the exhaust port at the top of the
hopper.
Filter maintenance
1. Open filter canister and clean filter element
on a daily basis using compressed air.
2. Change filter cartridge every 6 months
(Sooner if process materials are dusty.).
Never operate dryer without filter element installed.
Dryer Cleaning
Always unplug the dryer before cleaning.
The dryer is supplied with a surface coating that
is easily cleaned and maintained by simply
wiping the dryer with a moistened cloth or rag.
Never clean the dryer with solvents or corrosive
liquids. Always allow the dryer to cool
completely before cleaning.
ROUTINE OPERATION &
MAINTENANCE
PROCEDURES
Cont’d