User Manual

Table Of Contents
108259F #103614 (F600) 6 Legend Brands, Inc.
TROUBLESHOOTING
FAULT CAUSE SOLUTION
Water drips out
when moving unit
Unit was unplugged before
purging was complete.
Purge unit before moving. See “At the End of the Job.
Unit does not
operate
Unit not switched on.
No power to machine.
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Unit operating,
but room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Make sure “Humidistat” is OFF.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Unit collects too
little water
Room air is dry.
Room temperature is too low.
Filter is full.
Coils are clogged.
Make sure “Humidistat” is OFF.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Replace as necessary.
Check coils. Clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department at 800-932-3030 for further assistance.
SPECIFICATIONS
Model LGR 6000Li (#103614 (F600))
Water removal AHAM
(80°F/60% RH)
100 pts. | 47.3 L / day
Water removal saturation
(90°F/90% RH)
204 pts. | 96.5 L / day
Process air (max.) 320 CFM
Dimensions
(H × D × W)
32.1 × 19.8 × 20.0 in.
81.5 × 50.3 × 50.8 cm
Weight 103 lbs. | 46.7 kg
Amps 6.6A
Volts 115V
Frequency 60Hz
Power 759W
Operating range 33°F100°F | 1°C38°C
Noise level (avg.)
53 dB
Drain hose
40 ft. | 12.2 m
Power cord
25 ft. | 7.6 m
Construction
Rotomolded shell
Safety
ETL certified CSA 22.2 no. 92
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
Order replacement air filters from your local distributor.
Part no. #100254 (F579) (24 pack).
Be sure to visit Warranty.LegendBrandsRestoration.com
and register your purchase. Your registration will help us
provide you with updated product information as needed.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
WARNING: This product and other substances
that may become airborne from its use contain
chemicals, including lead and phthalates, known to the
State of California to cause cancer, birth defects, or
other reproductive harm. For more information, go to
P65Warnings.ca.gov