Instructions / Assembly
2)Insert the Black Plastic Black Rubber Washer 3 onto the
faucet under the chrome plate as a protective base, as
shown in Figure A-4.
3)If the counter-top surface has a second faucet hole,
remove the protective cap and install the RO Faucet.
(Or, drill a hole on the sink or counter-top surface; this
requires a 1/2-inch Hollow Diamond Bit)
4)After the RO Faucet is positioned, install the Black
Plastic Plate onto the faucet under the sink or
counter-top, as shown in Figure A-4.
5)Install the Metal Lock Washer under the Black Plastic
Plate, then tighten the Nut to lock and secure the faucet
on the counter-top, as shown in Figure A-4.
6)Install the White Quick Connector onto the bottom of
the faucet`s threads, as shown in Figure A-4.
7)Connect the Yellow RO Tubing into the White Quick
Connector, as shown in System Diagram.
1)Insert the Two Black Rubber O-Ring onto the chrome plate and install the plate onto the RO
Faucet as a faucet base, as shown in Figure A-4.
RO Faucet Installation
Figure A-4
Place the rubber on top of the metal base
White quick connector
Nut
Lock Washer
Black Plate
Chrome Plate
Black Rubber Washer 2
Black Rubber Washer 3
Black Rubber Washer 1
Sink
1)Using a 1/4-inch bit to drill a 1/4-inch hole on the drain pipe that fits 1/4-Inch Black Tubing.
2)Install and fasten the Drain Saddle Valve onto the drain pipe and connects the Black RO
Tubing, as shown in Figure A-5.
1)Remove the filters from the filter housing then remove the plastic shrink wrap off the filter body.
2)Insert the filter inside the 1st Stage filter housing.
3)Use supplied wrench to secure the filter housing onto the main system, as shown in Figure A-6.
1st Stage- PP Sediment Filter(White)
1)Remove the filters from the filter housing then remove the plastic shrink wrap off the filter body.
2)Insert the filter inside the 2nd Stage filter housing.
3)Use supplied wrench to secure the filter housing onto the main system, as shown in Figure A-6.
2nd Stage - GAC Carbon Filter(Blue Caps)
1)Remove the filters from the filter housing then remove the plastic shrink wrap off the filter body.
2)Insert the filter inside the 3rd Stage filter housing.
3)Use supplied wrench to secure the filter housing onto the main system, as shown in Figure A-6.
3rd Stage - CTO Carbon Filter(Mesh Body)
*It is recommended to turn on the Flush Valve every two weeks to flush and clean the RO membrane.
(The maintenance frequency entirely depends on the local water quality.)
DRAIN SADDLE VALVE INSTALLATION
How to change the vertical Pre-filtration filters:
Figure A-6
Figure A-5
UnlockLock
04 05