Use and Care Guide

Maintaining Your 1000 Pro Series 13
Maintaining Your 1000 Pro Series
Replacing Your 1000 Pro Series’s Filters
Your 1000 Pro Series is equipped with a
I
Pod Filter(s) Status Light
to indicate when
you need to change your pod lters (based on typical usage).
This reminder is
controlled by a timer that will change the Pod Filter(s) Status Light
from white to red
every six months. This timer can be reset by following the last step in this section.
To maximize lter and appliance lifespan, it is very important to always ush the
F1
ULTRA+3 Hybrid Scrub , or alternative
F3
Chemical Scrub and the
F5
Polishing Scrub (if purchased separately), prior to installing them into your 1000 Pro Series.
For this step, you will need a towel, a container to catch water, and your Filter Flushing
Setup you assembled during installation.
1. Unplug
Z
110v Power Cord from the electrical outlet.
2. Shuto water ow to your appliance by turning the blue handle on the
C
1/4 in. Quick Connect Shuto Valve (see Installation Guide) connected to your
1000 Pro Series’s
BB
Source Input Port located at the back of the appliance.
3. Place your container below the
O
Water Dispenser Nozzle, then press the
K
Ambient Dispense Mode Button, quickly followed by pressing and holding the
N
Dispense Button to de-pressurize the system, by dispensing water into a cup until water
ow stops.
4. If you aren’t replacing the
F1
ULTRA+3 Hybrid Scrub (or one of the alternative
lters listed above), you can skip ahead to “Step 9” on page 14.
5. Disconnect the tubing running between our 1000 Pro Series’s
BB
Source Input Port
and the
C
1/4 in. Quick Connect Shuto Valve you just shuto, and place end of
the tubing into the container to catch any water that drains back.
6. Connect the open end of the tubing from your
G
Filter Flushing Setup to the
C
1/4 in. Quick Connect Shuto Valve that you just disconnected.
7. Connect the lter(s) listed above that you are replacing to the
G
Filter Flushing Attachment, and ush by opening the
C
1/4 in. Quick Connect Shuto Valve, until the water exiting the lter is clear. Be sure