Specifications

DRI-STEEM CRUV Electric Humidifier Installation, Operation, and Maintenance Manual • Page 25
Installation
Dispersion:
Rapid-sorb
4. Mount the dispersion tubes on the header with the slip
couplings or hose cuffs:
When installing slip couplings for 1½" (DN40) dispersion
tubes, take care not to shear O-rings.
Set slip coupling on header stub or dispersion tube so O-ring
is resting on face of tubing.
Rotate slip coupling while pushing it onto the tubing.
O-rings are lubricated at factory. If additional lubrication is
necessary, DO NOT use petroleum-based lubricant.
5. Allow the dispersion tubes to rest against the bottom of the duct.
6. Position the flange of the L-bracket so it is upstream of the tubes
when the assembly is rotated into position. Fasten the L-bracket
to the end of the dispersion tubes with the provided bolt, lock
washer, and flat washer.
7. Rotate the assembly up until the L-bracket aligns with the
mounting holes in the duct or air handler.
For 1½" (DN40) dispersion tubes:
Header pitch is duplicated in the L-bracket.
Dispersion tube and slip coupling must be fully engaged
on header stub for O-rings to provide a seal.
High end of L-bracket can be fastened tight to duct or air
handler.
Fastener on low end of L-bracket must be long enough
to compensate for pitch. Use a nut on both sides of
L-bracket and duct or air handler for stability.
2" (DN50) dispersion tubes
Fasten bracket to top of duct and use hose cuffs to
compensate for header pitch.
Before securing hose cuffs with hose clamps on
dispersion tube and header stub, verify that dispersion
tube orifices are directed perpendicular to airflow.
8. Verify that all fasteners are secure:
L-bracket to duct
Dispersion tubes to L-bracket
Hose clamps on 2" (DN50) tubes
Header support bracket fastener
9. Secure and seal the header escutcheon plate around the header.
mc_060210_1050 -NA
Note:
See Page 26 for steam supply and condensate
drain line connection instructions.