Figure 11-1:
Fill cup extension kit
A fill cup extension kit (Figure 11-1) is required for any of the
following:
• XT humidifier models 75 through 200 (fill cup extension kit
ships loose with these models)
• All XT humidifiers using Ultra-sorb or Rapid-sorb dispersion
• All XT humidifiers with more than 20' (6 m) maximum
developed length of tubing/pipe from humidifier to dispersion
assembly
mc_110110_1455
Installation
Fill cup extension kit
OM-7588
Fill valve adapter
Overflow elbow
Drain cup plate
Supply water hose (A)
Cylinder fill hose (B)
Overflow hose (C)
Fill cup
(see inset below)
OM-7629
Cylinder fill (B)
Supply water (A)
Overflow (C)
Fill cup
Fill connection
mc_102810_1430
Removing existing fill cup: XT models 5 through 50
If installing a fill cup extension kit for XT models 5 through 50, first
remove the existing fill cup as follows:
1. Remove steam cylinder from XT cabinet (if not already out).
See “Removing steam cylinder” on Page 10.
2. Expand spring clamps and slide them up cylinder fill hose and
supply water hose, and disconnect hoses from fill connection
and fill valve adapter.
3. Disconnect overflow hose from overflow elbow.
4. Fill cup is press fit into top of XT cabinet. Rock fill cup back
and forth while pushing up until it comes out, then remove fill
cup and hoses.
Installing fill cup extension kit: all XT models
1. Remove steam cylinder(s) from XT cabinet (if not already out).
See “Removing steam cylinder” on Page 10.
2. Route fill cup extension kit hoses into cabinet through fill cup
hole, and fasten extension bracket as shown with two screws
provided.
3. Cut supply water hose (small-diameter hose) (A) to length so it
can attach to fill valve adapter without kinking.
4. Expand spring clamp and slide it onto supply water hose (A)
far enough so it will not interfere, then push hose onto fill valve
adapter. Expand and slide spring clamp into place.
5. Cut cylinder fill hose (bottom, center hose) (B) to length so it
can attach to fill connection without kinking.
6. Expand spring clamp and slide it onto cylinder fill hose (B)
far enough so it will not interfere, then push hose onto fill
connection. Expand and slide spring clamp into place.
7. Cut overflow hose (C) to length so it can attach to overflow
elbow without kinking.
8. Push overflow hose onto overflow elbow. No spring clamp is
required on this connection.