Product Manual

3.3.1 Clearances with single wall pipe
CANADA
É.-U.
A
14.25" (362 mm) (from the
back of the blower box)
14.25" (362 mm) (from the back
of the blower box)
B
18" (457 mm)
18" (457 mm)
C
5" (127 mm)
5" (127 mm)
D
0" (0 mm)
0" (0 mm)
E
69" (175 cm) minimum
69" (175 cm) minimum
F
12’’ (305 mm)
12’’ (305 mm)
G
1’’ (25 mm)
1’’ (25 mm)
24" (610 mm) minimum
24" (610 mm) minimum
I
11" (279 mm)
11" (279 mm)
¹A minimum clearance to the left is required for maintenance or replacement of
components, however, a larger clearance is suggested.
3.3.2 Clearances with double wall connector
(The use of a single wall pipe assembly with a heat shield certified to
6 "combustible materials, can be used. Only in this case, the same
clearances apply as with a certified double pipe.)
CANADA
É.-U.
A
6.75" (171 mm) (from the
back of the blower box)
6.75" (171 mm) (from the back
of the blower box)
11.5" (292 mm)
11.5" (292 mm)
C
5" (127 mm)
5" (127 mm)
D
0" (0 mm)
0" (0 mm)
E
69" (175 cm) minimum
69" (175 cm) minimum
F
12’’ (305 mm)
12’’ (305 mm)
G
1’’ (25 mm)
1’’ (25 mm)
24" (610 mm) minimum
24" (610 mm) minimum
I
11" (279 mm)
11" (279 mm)
¹Recommended clearance, otherwise use the clearance provided by the double wall
black pipe manufacturer.
²A minimum clearance to the left is required for maintenance or replacement of
components, however, a larger clearance is suggested.