7.4 Thermostat installation
Thermostat use will help you maintain a constant temperature throughout the house. A fixed
wall mounted 24v thermostat is required.
Note: Thermostat manufacturer’s instruction always overrides the information
published in the following section.
Thermostat location
- Must be installed on an inside wall of the
house;
- Where it will be the least affected by
affected by air currents from a hot air outlet
or cold outside walls;
- Must be installed at a minimum of 55" (140
cm) above the floor;
- Must be installed at a minimum of 15’ (4.57
m) from the furnace and must not receive
radiation heat from the glass door.
Thermostat wiring
Before installing the thermostat, disconnect
the furnace from the outlet.
Use an 18 AWG 2 strand wire.
The terminal block is located at the back on
the left side of the furnace when facing it. It
is identified with the letter “T”.
Loosen the two screws in the middle of the
terminal block and insert the wires in the
terminal. Tighten the two screws.
Open the thermostat housing and connect
the wires following the manufacturer's
instructions.