User Manual

Table Of Contents
BST Testing (Shenzhen) Co.,Ltd. Report No.: BSTXD200414607301ER
Add: No.7, New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China
Certificate Search: http://www.bst-lab.com, Tel:400-882-9628, 8009990305, E-mail:christina@bst-lab.com
Page 18 of 36
9. ELECTROSTATIC DISCHARGE TEST
9.1.Block Diagram of ESD Test Setup
9.2.Test Standard
ETSI EN301489-1 V2.1.1 (2017-02)
ETSI EN 301 489-3 V2.1.1 (2017-03)
Severity Level 3 for Air Discharge at 8KV
Severity Level 2 for Contact Discharge at 4KV
9.3.Severity Levels and Performance Criterion
9.3.1.Severity level
Level
Test Voltage
Contact Discharge (KV)
Test Voltage
Air Discharge (KV)
1.
2
2
2.
4
4
3.
6
8
4.
8
15
X.
Special
Special
9.3.2.Performance criterion: B
9.4.EUT Configuration on Test
The configuration of EUT are listed in Section 3.2.
9.5.Operating Condition of EUT
9.5.1.Setup the EUT as shown in Section 9.1.
9.5.2.Turn on the power of all equipments.
9.5.3.Let the EUT work in test mode (On) and test it.
Remark: is Discharge Electrode
EUT
AC Mains
AC Mains
ESD
Tester
0.8 m