User Manual

Table Of Contents
SECTION 10 BATTERY MANAGEMENT PAGE 171
9711-26400-0001
EXPORT CONTROLLED SEE PAGE 3
Rev -
NOTE
The conditioning process can take 3-
5 hours to complete. Ensure
external power remains connected for the duration of the
conditioning period.
NOTE
If the internal battery temperature exceeds 45°C during conditioning,
the charging circuit will suspend the conditioning cycle until the
temperature drops back into the normal operating range.
Table 33. Conditioning a Battery
STEP ACTION CONDITION OR INDICATION
1.
Connect external power.
2.
Open the Battery and Charger Monitor
page in ARMORutils
and Click on the
Conditioning Menu button.
The Battery Conditioning window opens,
as shown in Figure 89.
3.
Select Bay 1 Only, Bay 2 Only or All
Bays
4.
Click on Start Cycle.
5.
To terminate the conditioning process at
any time, click on Terminate Cycle.