User manual

Tamarisk
®
320
Software ICD
20
Response Format:
Table 23Data Transfer Upload Packet Response Format
Byte Value Description
1 0x01 Start of message.
2 0x72 Data Transfer Upload Setup Command ID.
3 0x06 Parameters length.
4, 5 unsigned integer Response ID. See table below.
6, 7 unsigned integer Packet number. First packet is 0.
8 checksum Frame check sequence.
Table 24Data Transfer Upload Packet Response ID
ID Description CU Response
3‡ Packet out of order.
Restart transmission from the packet number
included in the message.
4
Upload complete. Flash operations
underway.
CU should cease transmission of packets
until follow-up message is received.
5 Transfer CRC error. CU should cease data transfer operations
6 Data length error. CU should cease data transfer operations
8 Flash sector programming underway.
CU should stop transmitting packets and wait
for follow-up messages.
9 Flash sector programming complete. CU should resume transmission of packets.
10 Transfer complete. CU should cease data transfer operations.
‡The TIM shall send this response to the CU any time it detects a gap in the packet
number sequence. The packet number in the response shall be the packet number of the