Software ICD
22
4. FPA Name “FPA: U3600”
5. X1 Core Libraries Version – “X1 Core Lib Rel: 00.01.44”
6. RTL Logic Version String This is the version number of the current RTL logic
release. Example format: “RTL Rel: 01.00.0052”
Note: This is only an example. Some ASCII characters will change according to revision
levels in the system.
The TXT messages shall be followed by an ACK message.
Table 26System Version Get TXT Response Format (Multiple Responses)
Byte Value Description
1 0x01 Start of message.
2 0x00 TXT Response
3 N Parameters length.
4 to
(N+3)
Zero-terminated
text string
Length varies. Note trailing null is included in parameters
length.
(N+4) checksum Frame check sequence.
Table 27System Version Get TXT Response Format (Multiple Responses Verbose
Mode Enabled, Export Control 9-Hz Frame Rate Limited Mode)
Byte Value Description
1 0x01 Start of message.
2 0x00 TXT Response
3 N Parameters length.
4 to
(N+3)
Zero-terminated
text string
Length varies. Note trailing null is included in parameters
length. Example Response:
“System: Tamarisk-320
Rel: X1.P1.01.06.06
9Hz Enabled”
DRS Technologies
FPA: U3600”
X1 Core Lib Rel: 00.00.00
RTL Rel: 01.00.0066
(N+4) checksum Frame check sequence.
Table 28System Version Get ACK Response Format
Byte Value Description
1 0x01 Start of message.