User manual
Tamarisk
®
320
Software ICD
28
Table 40 – Digital Video Source IDs (RTL Rel: newer than 01.00.0080)
Source ID Description
0 Output of Uploaded Test Pattern
6
14 bit data with no invert/revert, no gray or freeze frame during
auto-calibrations
7
4 bit data with 1 frame of latency with invert/revert, gray or
freeze frame support during auto-calibrations
NOTE: ICE mode must be disabled prior to changing to video
tap 7 please see section 3.3.2.
8 Output of AGC Module.
9 Output of Symbology Module.
All other values reserved.
Table 41 – Digital Video Source IDs (RTL Rel: 01.00.0080 or prior)
Source ID Description
4 14 bit data, output of zoom module
5 Output of AGC Module
All other values reserved.
Response Format:
Table 42 – Digital Video Source Select Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x00D7 Digital Video Source Select Command ID.
6 checksum Frame check sequence.
3.1.8 Baud Rate Set – 0xF1
Description: Set the baud rate for the RS232 serial port. The system must be using RS-
232 serial for this command to have an effect.