User manual

Tamarisk
®
320
Software ICD
30
Command Format:
Table 45System Status Get Command Format
Byte Value Description
1 0x01 Start of message.
2 0xF2 System Status Get Command ID.
3 0x00 Parameters length.
4 checksum Frame check sequence.
Response Format:
Two responses are generated, a system status get response and an ACK response.
Table 46System Status Get First Response Format
Byte Value Description
1 0x01 Start of message.
2 0xF2 ACK Response
3 0x10 Parameters length.
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
4
(deprecated)
(deprecated)
EXTVID
0=in
1=out
2=off
CAL
0=none
1=2 pt cold
2=2 pt hot
3=1 pt
4=1 pt no
shutter
5
AGC
0=off
1=log equal (auto)
2=manual
3=linear equal
(deprecated)
Always reads 3
SHUTTE
R
0=closed
1=open
(deprec
ated)
(deprec
ated)
POL
0=blk
1=wht
6
(deprecated)
Always reads 0x0
(deprecated)
7 Unsigned integer Deprecated
8, 9 Unsigned integer Manual Gain
10, 11 Unsigned integer Manual Level
12, 13 Unsigned integer Gain Bias
14, 15 Unsigned integer Level Bias
16, 17 Unsigned integer Deprecated (always 0).
18, 19 Unsigned integer Deprecated (always 0).
20 chksm Frame check sequence.