User manual
Tamarisk
®
320
Software ICD
32
Table 49 – Field Calibrate Type IDs
ID Description
3 1-point calibration.
4 1-point calibration with shutter disabled.
All other values reserved.
Response Format:
Table 50 – Field Calibrate Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0027 Field Calibrate Command ID.
6 checksum Frame check sequence.
3.2.2 Field Calibrate – Shutter Disable Set – 0x81
Description: Enables or disables the TIM shutter. When the shutter is disabled it is forced
closed and the shutter will ignore requests to open for field calibrations. When the shutter is
enabled, it will open and respond to requests to open or close.
Command Format:
Table 51 – Field Calibrate Shutter Disable Set Command Format
Byte Value Description
1 0x01 Start of message.
2 0x81 Field Calibrate Shutter Disable Set Command ID.
3 0x02 Parameters length.
4, 5 Unsigned integer
0 = open and enable the shutter
1 = close and disable the shutter.
6 checksum Frame check sequence.
Response Format:
Table 52 – Field Calibrate Shutter Disable Set Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response