User manual

Tamarisk
®
320
Software ICD
34
4, 5 0x00AC Automatic calibration toggle command ID.
6 checksum Frame check sequence.
3.2.4 Automatic Calibration Period Set 0x12
Description: This command shall set the period between automatic calibrations (autocal
period). This command does not store the autocal period in non-volatile storage to be
preserved across power cycles. A setting of zero (0) is will prevent only periodic automatic
calibrations, not all automatic calibrations.
The default for time based automatic calibrations is five minutes.
Command Format:
Table 56Automatic Calibration Period Set Command Format
Byte Value Description
1 0x01 Start of message.
2 0x12 Automatic calibration period set command ID.
3 0x02 Parameters length.
4, 5 Unsigned integer Automatic calibration period in minutes.
6 checksum Frame check sequence.
Response Format:
Table 57Automatic Calibration Period Set Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0012 Automatic calibration period set command ID.
6 checksum Frame check sequence.
3.2.5 Automatic Calibration Period Get 0x13
Description: This command shall retrieve the period between automatic calibrations
(autocal period).