Command Format:
Table 58 Automatic Calibration Period Get Command Format
Byte Value Description
1 0x01 Start of message.
2 0x13 Automatic calibration period get command ID.
3 0x00 Parameters length.
4 checksum Frame check sequence.
Response Format:
Table 59Automatic Calibration Period Get TXT Response Format
Byte Value Description
1 0x01 Start of message.
2 0x00 TXT Response
3 N Parameters length.
4 to
(N+3)
Zero-terminated
text string
Message content example:
Example:
AUTOCAL: Interval= 300 sec.
Note trailing null is included in parameters length.
(N+4) checksum Frame check sequence.
Table 60Automatic Calibration Period Get ACK Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0013 AutoCal Period Get Command ID.
6 checksum Frame check sequence.
3.2.6 Automatic Calibration Activity Control 0x26
Description: This command shall control whether all automatic calibrations (autocal,
including range changes) are enabled or disabled. This command does not store calibration
activity mode in the NV Param. See section 3.5 for storing in NV Param.