User manual

Tamarisk
®
320
Software ICD
39
1 enables ICD mode.
6 checksum Frame check sequence.
Response Format:
Table 69ICE Mode Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0023 ICE Enable Command ID.
6 checksum Frame check sequence.
3.3.3 ICE Mode Strength Command 0x1E
Camera RTL Rel version 01.00.4471 or newer is required.
Description: Sets ICE Strength. (ICE Mode must be enabled before this command will
have any effect). This command, enables the user to select an ICE strength from 0-7 in 1
unit increments. The lowest setting is 0; the highest setting is 7. Recommend using lower
values when looking at lower contrast scenes and higher values when looking at dynamic
scenes.
Command Format:
Table 70ICE Mode Strength Command Format
2 0x1E ICE Mode Strength Command ID.
3 0x02 Parameters length.
4, 5 0x0000…0x0007 ICE Strength value.
6 checksum Frame check sequence.
Response Format:
Table 71ICE Mode Strength Response Format
4, 5 0x001E ICE Mode Strength Command ID.
6 checksum Frame check sequence.
3.3.4 ICE Mode High-Frequency Threshold Command 0x1F(Deprecated, please use
command 0x1E for ICE adjustments)
Camera RTL Rel version 01.00.4189 or newer is required together with compatible
CPU(Rel) version.