User manual

Tamarisk
®
320
Software ICD
40
Description: This command is preserved for backward compatibility with previous ICE
implementation and maps the 0-1023 input scale to the new ICE strength scale found in
cmd 0x1E.
Command Format:
Table 72ICE Mode High-Frequency Threshold Command Format
Byte Value Description
1 0x01 Start of message.
2 0x1F ICE Mode High-Frequency Threshold Command ID.
3 0x02 Parameters length.
4, 5 0 to 1023 ICE high-frequency threshold value.
6 checksum Frame check sequence.
Response Format:
Table 73ICE Mode High-Frequency Threshold Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x001F ICE Mode High-Frequency Threshold Command ID.
6 checksum Frame check sequence.
3.3.5 AGC Mode Set 0x2A
Description: Sets the operating mode for Automatic Gain Control.
NOTE
This command has no effect if ICE is enabled.
Command Format:
Table 74AGC Mode Set Command Format
Byte Value Description
1 0x01 Start of message.
2 0x2A AGC Mode Set Command ID.
3 0x02 Parameters length.