User manual

Tamarisk
®
320
Software ICD
42
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0028 AGC Mode Command
6 checksum Frame check sequence.
3.3.7 AGC White-Hot Polarity Set 0x29
Description: Commands the system to display hotter objects in the image as lighter
(whiter) and cooler objects as darker. This is the default.
Command Format:
Table 79AGC White Hot Polarity Set Command Format
Byte Value Description
1 0x01 Start of message.
2 0x29 AGC White-Hot Polarity Set Command ID.
3 0x00 Parameters length.
4 checksum Frame check sequence.
Response Format:
Table 80AGC White Hot Polarity Set Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0029 AGC White-Hot Polarity Set Command ID.
6 checksum Frame check sequence.
3.3.8 AGC Manual Gain Set 0x32
Description: Sets gain value used by AGC when configured to Manual Mode.
NOTE
This command has no effect if ICE is enabled.