User manual

Tamarisk
®
320
Software ICD
45
Response Format:
Table 86AGC Gain Bias Set Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0082 AGC Gain Bias Set Command ID
6 checksum Frame check sequence.
The gain factor computed for each bias setting is a two - piece formula.
For gain_bias <= 2047, gain_factor = (0.75*gain_bias/2047)+0.25
For gain_bias >= 2048, gain_factor = (3*(gain_bias-2048)/2047)+1
Figure 4– Gain Factor Curve
3.3.11 AGC Level Bias Set 0x83
Description: Sets level bias value. Level bias is similar to a brightness control.
0.0000
0.2500
0.5000
0.7500
1.0000
1.2500
1.5000
1.7500
2.0000
2.2500
2.5000
2.7500
3.0000
3.2500
3.5000
3.7500
4.0000
0
256
512
768
1024
1280
1536
1792
2048
2304
2560
2816
3072
3328
3584
3840
4096
Gain Bias
Gain Bias Parameter