User manual
Tamarisk
®
320
Software ICD
50
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x84 AGC ROI Get Command ID.
6 checksum Frame check sequence.
Table 96 – AGC ROI Get Response 1 Format
Byte Value Description
1 0x01 Start of message.
2 0x00 Text message.
3 0x39 Parameters length.
4-56
Zero-terminated
string.
Example:
“AGC ROI (x0,y0,x1,y1): ( 0, 0, 319,239)”
(Each coordinate value takes up 3 characters).
57 checksum Frame check sequence.
Command Format (sub-command 0x0001, Get Limit):
Table 97 – AGC ROI Get Limit Command Format
Byte Value Description
1 0x01 Start of message.
2 0x84 AGC ROI Get Limit Command ID.
3 0x02 Parameters length.
4,5 0x0001 Sub-command Get Internal ROI Limit.
6 checksum Frame check sequence.
Response Format:
Table 98 – AGC ROI Get Limit Response 1 Format
Byte Value Description
1 0x01 Start of message.
2 0x00 Text message.
3 0x39 Parameters length.
4-56
Zero-terminated
string.
Example:
“AGC ROI (x0,y0,x1,y1): ( 0, 0, 319,239)”
(Each coordinate value takes up 3 characters).
57 checksum Frame check sequence.
Table 99 – AGC ROI Get Limit Command ACK Response Format
Byte Value Description
1 0x01 Start of message.