User manual
Tamarisk
®
320
Software ICD
75
WARNING
Disabling temperature compensation should only be used in a debug
environment with test patterns. Disabling temperature compensation will
result in severely degraded performance.
Command Format:
Table 143 – Tcomp Disable Command Format
Byte Value Description
1 0x01 Start of message.
2 0x18 Tcomp Disable Command ID.
3 0x02 Parameters length.
4 to 5
0 = enable
1 = disable.
Disable/enable. Note value of 1 disables Tcomp.
6 checksum Frame check sequence.
Response Format:
This command results in an ACK message.
Table 144 – Tcomp Disable ACK Response Format
Byte Value Description
1 0x01 Start of message.
2 0x02 ACK Response
3 0x02 Parameters length.
4, 5 0x0018 Tcomp Disable Command ID.
6 checksum Frame check sequence.
3.7.3 Test Pattern Select – 0xF4
Description: Enables and selects a video test pattern. Selecting test pattern <0x0000>
disables the test pattern generator. This test pattern replaces the input video stream from the
FPA and facilitates testing of downstream processing blocks.
This requires a sequence of commands. The current mode of operation can also affect how
the test patterns look and the actual pixel values on the digital interfaces. Using a pre AGC
video tap (14 bit data) will allow for pixel data validation.
Also, note if automatic calibration has not been disabled or a range change occurs while a
test pattern is selected the test pattern will be corrupted.
The to avoid these issues command sequence should be as follows: