manual control of the remote control (see fi g. 2).
In addition, the remote control can also be used to set a
number of additional functions:
- temperature display in degrees Celsius or Fahrenheit;
- time;
- thermostat function;
- timer for thermostat function.
Although highly improbable, we cannot
rule out that your appliance’s ignition
process can be started unintentionally
through other remote controls.
This could be the remote control of your
neighbours' gas heater, but also car keys
and garage door openers.
The result will be that your appliance will
burn when you do not want it to.
Unintended ignition of your appliance could be solved/pre-
vented by:
- setting a new communication code between remote con-
trol and receiver (see section 4.2.1);
- when left unattended for a longer period, set button A on
the gas control to the position MAN (see section 4.2.2.1);
- close the gas tap near your appliance. This is the safest
precaution, if the appliance will not be used for a longer
period;
- Observe stated precautions / safety instructions - even if
the appliance is not in use.
4.2.1 Setting the communication code
Prior to putting the application into operation, a communi-
cation code must be set between the remote control and
the receiver. The code is chosen randomly from the 65000
available codes. As a result, the chance that other remote
controls near you are using the same code and affect the
operation of your appliance is very small.
Follow the procedure described below:
Hold down the reset button on the receiver, until you
hear two consecutive sound signals (see fi g. 3).
After the second, longer signal, let go of the reset button.
Press button
(small fl ame) or button (large fl ame) on
the remote control within 20 seconds, until you hear an
extra long sound signal: this is the confi rmation of a
correct communication.
!Caution When installing a new remote control or
receiver, you must set a new communica-
tion code.
4.2.2 MAN position
By briefl y pressing the SET button, you will go through the
following functions:
MAN TEMP TEMP (P*)TIMER MAN
where, depending on the timer setting:
(P*) is displayed as P1 , P1 , P2 , P2
!Tip You can also go back to the MAN position
by pressing the button
(large fl ame) or
(small fl ame).
!Caution - When pressing the buttons (with the ex-
ception of the SET button), the transmis-
sion symbol ( ) will appear to indicate
that transmission is taking place between
the remote control and the receiver;
- The receiver acknowledges the transmis-
sion with a sound signal;
- The appliance will automatically enter the
standby position, if there is no transmis-
sion for 6 hours.
• Set the remote control to the MAN position.
4.2.2.1 Ignition
- During the ignition process, you are not
allowed to operate control button B on
the gas control manually (see fi g. 4);
- Always wait 5 minutes after the pilot
burner has gone out, before you re-ignite
the appliance;
- Close the gas tap in case of malfunctions
and/or poor operation and warn the
installer.
2
3
Caution
Caution