SDS

Table Of Contents
6.4 Reference to other sections
Hazardous combustion products: see section 5. Personal protective equipment: see section 8. Incompatible materi-
als: see section 10. Disposal considerations: see section 13.
SECTION 7: Handling and storage
7.1 Precautions for safe handling
Recommendations
- Measures to prevent fire as well as aerosol and dust generation
Use local and general ventilation. Take precautionary measures against static discharge. Use only in well-ventilated
areas. Ground/bond container and receiving equipment.
- Specific notes/details
Dust deposits may accumulate on all deposition surfaces in a technical room. The product in the delivered form is not
dust explosion capable; the enrichment of fine dust however leads to the danger of dust explosion.
Advice on general occupational hygiene
Wash hands after use. Do not eat, drink and smoke in work areas. Remove contaminated clothing and protective
equipment before entering eating areas. Never keep food or drink in the vicinity of chemicals. Never place chemicals
in containers that are normally used for food or drink. Keep away from food, drink and animal feedingstuffs.
7.2 Conditions for safe storage, including any incompatibilities
Managing of associated risks
- Explosive atmospheres
Removal of dust deposits.
- Ventilation requirements
Use local and general ventilation.
7.3 Specific end use(s)
See section 16 for a general overview.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Occupational exposure limit values (Workplace Exposure Limits)
Coun-
try
Name of agent CAS No Identi-
fier
TWA
[ppm]
TWA
[mg/m³]
STEL
[ppm]
STEL
[mg/m³]
Ceiling-C
[ppm]
Ceiling-C
[mg/m³]
Nota-
tion
Source
US particulates not
otherwise classi-
fied
REL appx-D NIOSH
REL
US particulates not
otherwise classi-
fied (PNOC)
PEL 1,766 15 partml,
i, dust
29 CFR
1910.10
00
US particulates not
otherwise classi-
fied (PNOC)
PEL 529.5 5 partml,
r, dust
29 CFR
1910.10
00
US Particulates not
otherwise regu-
lated
PEL
(CA)
10 dust Cal/
OSHA
PEL
US Particulates not
otherwise regu-
lated
PEL
(CA)
5 r Cal/
OSHA
PEL
Safety Data Sheet
acc. to 29 CFR 1910.1200 App D
DRYLOK® Fast Plug
Version number: REV 5.0
Replaces version of: 2022-12-09 (REV 4)
Revision: 2022-12-09
United States: en
Page: 4 / 15