Specification
Table Of Contents
- PART 1 - GENERAL
- 1.1 RELATED DOCUMENTS
- 1.2 SUMMARY
- 1.3 references
- 1.4 ACTION SUBMITTALS
- 1.5 QUALITY ASSURANCE
- A. Comply with Section 01 40 00.
- B. Qualifications:
- 1. Manufacturer Qualifications: Company with minimum 15 years of experience in manufacturing of specified products and systems.
- 2. Applicator Qualifications: Company with minimum of 5 years’ experience in application of products as specified in this section on projects of similar size and scope, and employs installers and supervisors who are trained by and acceptable to produ...
- C. Field Mock-up:
- 1. Install at Project site or pre-selected area of building an area for field mock-up, as directed by Architect.
- 2. Apply material in strict accordance with manufacturer’s written application instructions.
- 3. Manufacturer’s representative or designated representative will review technical aspects; surface preparation, application, and workmanship.
- 4. Field sample will be standard for judging workmanship on remainder of Project.
- 5. Maintain field mock-up during construction for workmanship comparison.
- 6. Do not alter, move, or destroy field mock-up until Work is completed and approved by Architect.
- 7. Obtain Architect’s written approval of field mock-up before start of material application, including approval of aesthetics, color, texture, and appearance.
- 1.6 DELIVERY, STORAGE, AND HANDLING
- A. Comply with Section 01 60 00.
- B. Comply with manufacturer’s ordering instructions and lead-time requirements to avoid construction delays.
- C. Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact.
- D. Transport and store in unopened containers and keep in clean, dry condition protected from rain, dew, and humidity.
- 1.7 PROJECT CONDITIONS
- PART 2 - PRODUCTS
- 2.1 MANUFACTURERs
- A. Subject to compliance with requirements, provide products from the following manufacturer:
- B. Substitutions: Not Permitted.
- C. Specifications and Drawings are based on manufacturer's proprietary literature from United Gilsonite Laboratories (UGL).
- D. Single Source Limitation for Complete System: Obtain materials from a single manufacturer to create a complete system.
- 2.2 MATERIALS
- A. Water based cleaner and degreaser for concrete surfaces.
- B. Latex and cement-based patch system with integrated bonding agent for concrete, brick and mortar and masonry.
- C. Sulfamic Acid powder for cleaning and etching concrete, stone, tile, galvanized metal and brick,
- D. Fast-setting Hydraulic Cement for patching cracks and holes in masonry and anchoring metal to masonry.
- E. Latex Bonding Agent to adhere new concrete, stucco, stone and plaster to structurally sound existing concrete, stone, gypsum board, hardboard and plaster.
- F. Pre-mixed liquid for cleaning and etching concrete, stone, tile, galvanized metal and brick,
- G. Lightweight aggregate non-skid texture additive for oil base, latex base, epoxy floor paints and clear coatings.
- H. Siliconized acrylic gun-grade latex filler for sealing cracks and mortar joint in masonry walls, sidewalks, steps or floors.
- I. Siliconized acrylic pourable latex filler for sealing cracks and mortar joints in masonry walls, sidewalks, steps or floors.
- 2.3 mixing
- 2.1 MANUFACTURERs
- PART 3 - EXECUTION
SECTION 03 01 00
DRYLOK
®
Concrete and Masonry Repair and Maintenance Products
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Accessories for Concrete and Masonry repair and maintenance as scheduled including the
following:
a. DRYLOK
®
Concrete Cleaner and Degreaser.
b. DRYLOK
®
Concrete Patch.
c. DRYLOK
®
Etch.
d. DRYLOK
®
Fast Plug
®
Hydraulic Cement.
e. DRYLOK
®
Latex Bonding Agent.
f. DRYLOK
®
Liquid Etch.
g. DRYLOK
®
Non-Skid Texture Additive.
h. DRYLOK
®
Masonry Crack Filler.
i. DRYLOK
®
Pourable Masonry Crack Filler.
.
B. Related Sections:
1. Section 03 30 00 – Cast-in-Place Concrete.
2. Section 03 41 00 – Precast Structural Concrete.
3. Section 03 47 13 – Tilt-Up Concrete.
4. Section 04 21 00 – Masonry Assemblies Unit Masonry.
5. Section 04 22 00 – Concrete Unit Masonry
6. Section 09 97 26 – Cementitious Coatings
1.3 REFERENCES
A. ASTM International (ASTM)
1. ASTM D 16 – Standard Terminology for Paint, Related Coatings, Materials and
Applications.