Instruction manual

13
Door Chime Feature
The door chime feature is used to provide a tone from the keypad each time a door or window is
opened or closed. The doors and windows which will provide this indication are programmed by your
installer.
To activate the door chime from an LED Keypad:
Enter [][4] to turn the door chime feature ON and OFF. When the command is entered, the keypad
buzzer will beep 3 times if the door chime feature is enabled and will sound one long beep if it is
disabled.
To activate the door chime from an LCD Keypad:
Press [] to enter the function list, then scroll to find...
Press [
] or [4] to enable or disable the Door Chime feature. Press [#] to return to
the Ready state.
Fire Alarm Operation
Alarm
On a fire alarm, the bell or siren will pulse ON and OFF. The transmission of the alarm to the monitoring
station is delayed for 30 seconds. If the alarm is not cleared within the 30 second delay, the it will be
transmitted to the monitoring station.
Silence
To silence the bell or siren, press the [#] key. If the alarm is silenced and the smoke detector is not
reset, the alarm will resound after 90 seconds.
Resetting Smoke Detectors
Once the smoke detector is reset, if it still detects smoke, the alarm sequence will resound as
described above. If there is no smoke, the system will return to normal.
To reset smoke detectors from an LED Keypad:
Press [][7][2].
To reset smoke detectors from an LCD Keypad:
Press [] to enter the function list. Scroll to find:
Press [] to select the output control. The display will read...
Use the arrow (< >) keys to find the following message and press the [] key to
select...
NOTE: If you suspect that a fire alarm has transmitted and that there is no fire condition, call the
monitoring station to avoid an unnecessary response.
If a fire condition is apparent, follow your
evacuation plan immediately. If the alarm sounds at night, evacuate immediately.
NOTE: The description above may not be applicable depending on how your installer has
programmed the fire alarm operations on your system. Ask your installer for more information
regarding your system's operation.
Press (*) For<>
Door Chime
Press (*) For <>
Output Control
Select Output <>
Command O/P 1
Select Output <>
Command O/P 2