PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. NOTE: These instructions shall be used in conjunction with the system Installation Manual of the Control Panel with which this equipment is intended to be used.
The PK5500 keypad can be used on security systems with up to 64 zones. These keypads are compatible with the latest version of the folllowing DSC security systems: •PC580 •PC585 •PC1555MX •PC1565 •PC1616 •PC1832 •PC1864 •PC5005 •PC5008 •PC5010 •PC5015 •PC5016 •PC5020 3 Specifications • Temperature range: -10°C to +55°C (14°F to 131°F) • Humidity (MAX): 93%R.H.
Programming the Keypad There are several programming Toggle Option options available for the keypad. These are described below. Pro1_ _ 4 _ _ _ _ gramming the keypad is similar to programming the rest of the system. When you are in the keypad programming sections, the keypad will display which options are turned on along the top of the display. To turn an option on or off, press the number corresponding to the option on the number pad.
Limited Warranty Digital Security Controls warrants that for a period of 12 months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot.
Keypad Enrollment Enter keypad programming by pressing [,][8][Installer’s Code][000].
[065] Fire Alarm Label (28 Characters) Default:“Fire Zone” I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [065] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [066] Fail to Arm Event Message Default: “System Has Failed to Arm” I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [066] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [067] Alarm When Armed E
[074] Key Options Default ON ON ON OFF I____I I____I I____I I____I Option 1 2 3 4-8 ON [F]ire Key Enabled For Future Use [P]anic Key Enabled For Future Use OFF [F]ire Key Disabled [P]anic Key Disabled [076] First Keypad Options Default ON ON OFF ON OFF ON OFF OFF Option ON I____I 1 Display Code when Programming I____I 2 Local Clock Display ON I____I 3 Local Clock Displays 24-hr Time I____I 4 Auto Alarm Memory Scroll Enabled I____I 5 Local Display of Temperature ON I____I 6 Bypass Options prompt ON I__
[120]-[151] Command Output Labels Default: “Command_O/P_1” - “Command_O/P_4” For Partition 1 Command O/P 1 to 4 enter [120] to [123] For Partition 2 Command O/P 1 to 4 enter [124] to [127] For Partition 3 Command O/P 1 to 4 enter [128] to [131] For Partition 4 Command O/P 1 to 4 enter [132] to [135] Section [120]-[151] For Partition 5 Command O/P 1 to 4 enter [136] to [139] For Partition 6 Command O/P 1 to 4 enter [140] to [143] For Partition 7 Command O/P 1 to 4 enter [144] to [147] For Partition 8 Comma