Installation manual

38
OFF LINKS is backup of Land Line(s).
The control panel will dial through the LINKS if the panel is
having difficulty communicating over the phone line. For each failed attempt to the land line,
one attempt will be made to the LINKS1000.
8 Delinquency ON Delinquency Follows Zone Activity (Activity Delinquency).
This feature assists in the mon-
itoring of the elderly and the handicapped. If there is no zone activity on a partition, the Delin-
quency Transmission Delay timer in Section [370] will begin counting in hours. When the
counter reaches the programmed time, the panel will communicate the Delinquency Code to
the central station, if programmed. If there is zone activity present on the system at any time,
the counter will be reset. If this option is used, the Closing Delinquency option is not available.
NOTE: This code will not be transmitted for partitions that are Away armed. Activity
on bypassed zones does not affect this timer. The timer is reset on arming.
OFF Delinquency Follows Arming (Closing Delinquency).
This reporting code is sent whenever
the programmed number of days for Delinquency has expired without the partition being
armed. The timer for this feature is programmed in Section [370]. The value programmed in this
section determines the number of days of no-arming the partition counts before sending the
Delinquency reporting code to the central station. Once this code is sent, the timer will not be
started again until the partition has been armed. Each day programmed in the counter repre-
sents one day PLUS the time it takes for the partition to reach midnight. This feature may be dis-
abled by programming 000 in Section [370].
[380] - FIRST COMMUNICATOR OPTION CODES
Option Communicator Code On/Off Description
[381] - SECOND COMMUNICATOR OPTION CODES
Option Communicator Code On/Off Description
1 Opening After Alarm Keypad
Ringback
ON Opening After Alarm Keypad Ringback Enabled.
When the Opening After Alarm reporting
code is successfully transmitted to a programmed telephone number, the keypad will sound a
series of 8 beeps to confirm to the end user that the Opening After Alarm code was sent and
received. This ringback will occur for each Opening After Alarm code successfully reported.
OFF Opening After Alarm Keypad Ringback Disabled
2 Opening After Alarm Bell
Ringback
ON Opening After Alarm Bell Ringback Enabled
. When the Opening After Alarm reporting
code is successfully transmitted to a programmed telephone number, the bell will sound a series
of 8 squawks to confirm to the end user that the Opening After Alarm code was sent and
received. This ringback will occur for each Opening After Alarm code successfully transmitted.
OFF Opening After Alarm Bell Ringback Disabled
3 SIA Reporting Codes ON SIA Sends Programmed Reporting Codes.
This option is for use with the SIA communication
format.). If 00 is programmed in the reporting code section, the event will not be communi-
cated. When this option is ON and there is a valid reporting code programmed in the reporting
code section, the programmed reporting code will be transmitted. If FF is programmed as a
reporting code, the event will not be communicated.
Reporting Code Entry Option ON Option OFF
00 No Transmission No Transmission
FF No Transmission Auto Reporting Code sent
01-FE 01-FE sent Auto Reporting Code sent
OFF SIA Sends Automatic Reporting Codes
. When this option is OFF and there is a valid reporting
code (01-FE) or FF programmed in the reporting code section, the panel will transmit an auto-
matic reporting code for SIA only. This would be used when automatic reporting codes are
required but there is a requirement for a different reporting code (e.g., Pager format, etc.).
4 Closing Confirmation ON Closing Confirmation Enabled
. When a Closing reporting code is successfully transmitted to
a programmed telephone number, the keypad will sound a series of 8 beeps to confirm to the
end user that the Closing code was sent and received.
OFF Closing Confirmation Disabled.
There will be no keypad ringback when a Closing reporting
code is successfully transmitted to a programmed telephone number.
5 Talk/Listen Options for
Phone Number One/Three
ON Talk/Listen (PC5936) on Phone #1/3 Enabled.
If Talk/Listen is requested for an event by the
PC5936, the panel will request the session on the next communication on phone number 1/3
(via L-Block) to the central station.
OFF Talk/Listen (PC5936) on Phone #1/3 Disabled.
The panel will not request a Talk/Listen session
for an event even if the PC5936 has requested it.
6 Talk/Listen Options for
Phone Number Two
ON Talk/Listen (PC5936) on Phone #2 Enabled.
If Talk/Listen is requested for an event by the
PC5936, the panel will request the session on the next communication on phone number 2 (via
L-Block) to the central station.
OFF Talk/Listen (PC5936) on Phone #2 Disabled.
The panel will not request a Talk/Listen session
for an event even if the PC5936 has requested it.
7 Contact I.D. Reporting Codes ON Contact I.D. Uses Programmed Reporting Codes.
The Contact I.D. communications format
will use programmed reporting codes when transmitting to the central station.
OFF Contact I.D. Uses Automatic Reporting Codes.
The Contact I.D. communications format will use
the automatic reporting codes as shown in Appendix C when transmitting to the central station.
8 Local Mode ON Local Mode Enabled.
The panel will always send events to the PC5108L module. Downlook
will not be initiated if requested.
OFF Local Mode Disabled.
The panel will only send events that are being communicated to the
PC5108L module. Downlook will be initiated when requested.