Installation manual

40
(Downloading Telephone Number) . . . . . . . . . . . . . . .Section [490]
Communicator Call Direction Options. . . . . . Section [351] to [376]
Call LINKS1000 as well as Land Line . . . . . Section [380], Option [7]
Maximum Dialing Attempts . . . . . . . . . . . . . . . . . . . .Section [165]
This 4-digit number can be used with long distance tele-
phone numbers that are dialed through the LINKS mod-
ule. These codes are used for programming area codes in
cases where a land line telephone number may be a local
call, while the cellular telephone number dialed by the
LINKS module is a long distance call.
[393] - LINKS Special Function Preamble
This Special Preamble is inserted before all other pream-
bles. It is used for dialing such cellular numbers as #DAT
and *DATA for reduced billing increments.
5.7 Downloading Options PWS Sect 7
Downloading
Downloading allows programming of the entire control
panel via a computer, modem and telephone line. All
functions and features, changes and status, such as Trou-
ble conditions and open zones can be viewed or pro-
grammed by downloading.
NOTE:
When power is applied to the panel, a 6-hour down-
loading window can be enabled. This will allow you to per-
form downloading without having to do any keypad
programming.
NOTE:
When an event occurs that the system is pro-
grammed to communicate to the central station, the panel
will disconnect from the downloading computer and report
the event. This will happen for all events except test trans-
missions.
If the Answering Machine/Double Call
Answering Machine/Double Call Answering Machine/Double Call
Answering Machine/Double Call option is enabled
(or during the first 6 hours after power up) the panel will
answer incoming calls for downloading provided the fol-
lowing conditions occur:
1. The panel hears one or two rings, then misses a ring.
2. At this point the panel will start a timer.
3. If the panel hears another ring before the Answering
Machine Double Call Timer expires it will answer on
the first ring of the second call.
The panel will immediately go on-line and begin the
download process unless the Call Back
Call BackCall Back
Call Back option is enabled.
If enabled, the panel and computer will both hang up.
The panel will then call the Download Computer Tele-
Download Computer Tele-Download Computer Tele-
Download Computer Tele-
phone Number
phone Number phone Number
phone Number and wait for the computer to answer.
Once the computer answers downloading will begin.
If the User-enabled DLS Window
User-enabled DLS Window User-enabled DLS Window
User-enabled DLS Window option is ON, the user
can activate the downloading feature by entering
[*][6][Master Code][5].
Six hours after power-up, the panel will not answer
incoming calls unless the Answering Machine/Double
Answering Machine/DoubleAnswering Machine/Double
Answering Machine/Double
Call
Call Call
Call option is enabled, or the Number of Rings
Number of Rings Number of Rings
Number of Rings is pro-
grammed to be more than [0].
If the User-Initiated Call-Up
User-Initiated Call-UpUser-Initiated Call-Up
User-Initiated Call-Up option is enabled, the user
can have the panel initiate a call to the downloading com-
puter by pressing [*][6][Master Code][6].
The Download Access Code
Download Access CodeDownload Access Code
Download Access Code and Panel Identifier Code
Panel Identifier CodePanel Identifier Code
Panel Identifier Code
are for security and proper identification. Both the panel
and the computer file should have the same information
programmed before attempting to download.
The time to complete a successful download can be signif-
icantly reduced with the use of the PC-Link. This adaptor
makes it possible to perform on-site downloading. To Ini-
Ini-Ini-
Ini-
tiate Local Downloading via the PC-Link
tiate Local Downloading via the PC-Linktiate Local Downloading via the PC-Link
tiate Local Downloading via the PC-Link, enter [
][8]
[Installer Code] [499] [Installer Code] [499]. All keypads
will be busy for the duration of the PC-Link connection.
The status LEDs will display the current system status on
the keypad where the PC-Link was initiated. For more
information on connecting the PC-Link, refer to your ’PC-
Link Download Kit Instruction Sheet’.
Downloading can also be performed through the
LINKS1000 cellular communicator if the telephone line is
disconnected. If using the LINKS1000 with Call Back, you
need to program the LINKS1000 Preamble
LINKS1000 Preamble LINKS1000 Preamble
LINKS1000 Preamble with the
downloading telephone number in order for the panel to
call the computer correctly.
NOTE:
When uploading labels from LCD keypads, the DLS
software will receive the labels only from the LCD keypad
assigned to slot 8. In addition, version 1.0 and version 2.0
LCD keypads are not compatible on the same system. For
more information refer to the Download Manual included
with the computer software.
NOTE:
The most recent version of the PKP-LCD keypad on
the system should be assigned to slot 8.
Answering Machine Double Call Timer . . . . . . . . . . . Section [405]
Download Computer Telephone Number . . . . . . . . . Section [402]
Download Access Code. . . . . . . . . . . . . . . . . . . . . . . Section [403]
Panel Identifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [404]
LINKS1000 Preamble (Downloading) . . . . . . . . . . . . . Section [490]