Installation manual

26
[66] Keypad Options
Default Option ON OFF
ON
I_______I 1 Display Access Code when Programming Display ‘X’ when Programming
ON
I_______I 2 Local Clock Display Enabled Local Clock Display Disabled
OFF
I_______I 3 Local Clock Displays 24 Hour time Local Clock Displays AM/PM
ON
I_______I 4 Auto Alarm Memory Scroll Enabled Auto Alarm Memory Scroll Disabled
OFF
I_______I 5 Local Display of Temperature Enabled* Local Display of Temperature Disabled
OFF
I_______I 6 Bypass Options prompt ON Bypass Options prompt OFF
OFF
I_______I 7-8 For Future Use
[67] Fifth User Display Mask
Default Option ON OFF
OFF I_______I 1 Thermostat CTRL Prompt ON* Thermostat CTRL Prompt OFF
OFF
I_______I 2 Temperature Setting Prompt ON* Temperature Setting Prompt OFF
OFF
I_______I 3 Occupancy Mode Prompt ON* Occupancy Mode Prompt OFF
OFF
I_______I 4 Thermostat Mode Prompt ON* Thermostat Mode Prompt OFF
OFF
I_______I 5 Fan Control Prompt ON* Fan Control Prompt OFF
OFF
I_______I 6 For Keypad View Prompt ON* For Keypad View Prompt OFF
OFF
I_______I 7-8 For Future Use
[68] Sixth User Display Mask
Default Option ON OFF
OFF
I_______I 1 Occupancy Mode Auxiliary Prompt ON* Occupancy Mode Auxiliary Prompt OFF
OFF
I_______I 2 Occupancy Mode Day Prompt ON* Occupancy Mode Day Prompt OFF
OFF
I_______I 3 Occupancy Mode Away Prompt ON* Occupancy Mode Away Prompt OFF
OFF
I_______I 4 Occupancy Mode Night Prompt ON* Occupancy Mode Night Prompt OFF
OFF
I_______I 5-8 For Future Use
NOTE: These options are only relevant if you are using an LCD5500Z v2.1 or higher or an LCD5520Z v3.1.
[97] View Software Version
[98] Initiate Global Label Broadcast
All LCD programming is done per keypad. If more than one LCD keypad are present on the system, and the PC5400 receives
labels, labels programmed at one keypad can be broadcast to all other LCD keypads. Perform the following procedure in order to
broadcast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter Installer’s Programming, then enter section [98] at the keypad that was programmed. The keypad will now broadcast
all the information programmed to all the other LCD keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.
[99] Reset LCD EEPROM to Factory Defaults
ASCII Characters