Specifications

K E Y P A D C O M M A N D S
18
[
]
[7] Command Output Functions
There are four output functions available to the user. Each function can be performed when the system is
either armed or disarmed.
[] [7] [1-4] – Command Output Option #1-4:
Press []
[7] [1-4] [Access Code, if required] to activate outputs programmed as PGM output option [19]-
[22]. These outputs can be used for operating devices such a garage door opener, lighting or door strikes.
Special Note: [] [7] [2] – Command Output Option #2:
Press []
[7] [2] [Access Code, if required] to activate all outputs programmed as
one of
PGM output
options [03], [04] or [20].
Traditionally, [] [7] [2] has been reserved for resetting smoke detectors. Smoke detectors should now be
programmed as output [03] “Sensor Reset” or [04] “2-Wire Smoke”. Do not program output options [03],
[04] and [20] on the same system.
Sensor reset can also be performed by pressing and holding the Reset function key for two seconds.
Please see Section 5.10 “PGM Output Options” for more information.
[]+[8] Installer Programming
Enter [][8] followed by the Installer Code to enter Installer Programming
(See Section 4.0 “How to Program”).
[]+[9] Arming Without Entry Delay
When a Partition is armed with the [][9] command the panel will remove the entry delay from the
partition. After the exit delay, Delay 1 and Delay 2 type zones will be instant and Stay/Away zones will
remain bypassed.
(See Section 5.1 “Zone Definitions”).
A valid access code must be entered after pressing [] [9].
[]+[0] Quick Arm/Quick Exit
Quick Arm
If the Quick Arm Enable option is enabled the panel can be armed by entering [][0]. This is a useful
method of arming a Partition when someone without a User Code will be required to arm a Partition.
The Quick Arm feature must be enabled in order for the Stay/Away function keys to operate as
intended. If the feature is not enabled, the user will be required to enter their access code after
pressing the Stay or Away function key in order to arm the system in the stay or away mode.
Quick Exit
Quick Exit will allow someone to leave an armed premise through a Delay type zone without having to
disarm and rearm the system.
When [][0] is entered, if the Quick Exit Enabled option is enabled, the panel will provide a two minute
window to exit. During this time the panel will ignore the first activation of a Delay type zone. When the
Delay zone is secured the panel will end the two minute time period.
If a second Delay zone is tripped, or if the zone is not restored after two minutes, the panel will start entry delay.
The Quick Exit feature should not be used on Global Delay zones.
If Quick Exit is used on a partitioned system, Keypad Blanking and Access Code Required to Remove
Blanking should be enabled.
Code Required for Bypass ..................................... Section [015], Option [5]
Master Code Not Changeable option .................... Section [015], Option [6]
Quick Arm Enable ................................................... Section [015], Option [4]
Quick Exit Enable ................................................... Section [015], Option [3]
3.5 Function Keys
There are 5 function keys on the PC5010 keypads labelled Stay, Away, Chime,
Reset and Exit. The operation of these keys is described below. The function is
activated by pressing and holding the key for 2 seconds.
“Stay” - Stay Arm
Arms the partition to which the keypad is assigned. All Stay/Away type zones will be
automatically bypassed. Delay type zones will provide entry and exit delay. The
Quick Arm feature must be enabled for this key to function
(Section [015], Option
[4])
. If Quick Arming is not enabled, the user must enter their access code
after pressing the function key in order to arm the system in the Stay mode.
“Away” - Away Arm
Arms the partition to which the keypad is assigned. All Stay/Away type zones will be active at the end of
the exit delay. Delay type zones will provide entry and exit delay. The Quick Arm feature must be enabled
for this key to function
(Section [015], option [4])
. If Quick Arming is not enabled, the user must enter their
access code after pressing the function key in order to arm the system in the Away mode.