Maintenance Table of Contents Introduction 1 About Your Security System 1 Trouble and Armed LED Displays 2 System Information 3 Master Code Description 4 Arming “At-Home” Arming 4 5 Split Arming the Panel Disarming 5 5 If an Alarm Sounds Alarm Memory Display Zone Bypassing 6 6 6 Viewing Trouble Conditions LCD-600 Controls and Display Description 7 8 With normal use, the system requires minimum maintenance. The following points should be observed. 1.
Family Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly. It is thus very important that a family escape plan be developed and rehearsed. 1. Every family member should participate in developing the escape plan. 2. Study the possible escape routes from each location within the house and since many fires occur at night, special attention should be given to the escape routes from sleeping quarters. 3.
Testing To insure that your system continues to function as intended, it is important that you test the system weekly. See the testing procedure elsewhere in this manual. If your system does not function properly, call your installing company for service. Monitoring This system is capable of transmitting alarms, troubles, and emergency information over telephone lines to a monitoring station. If you inadvertently initiate an alarm, immediately call the monitoring station to prevent an unnecessary response.
Use the scroll keys to find the access code you wish to add, change or delete. PC1500 / PC1550: There are 5 codes (2...6). PC2500: There are 7 codes (2...8). PC3000: There are 15 codes (02...16). PC2550: Codes 2 through 8 are programmed like all others. For codes 9 to 16, enter [✱] [5] [Master Code] [9] followed by [1] to [8], representing 9 to 16. Then program codes. Remember, code number 1 is the Master Code and it should not be deleted.
Master Code The four digit Master Code is used for arming and disarming the security system, programming additional security codes and changing other features. The Master Code will be supplied to you by your installer. If enabled by your installer, the Master Code can be changed at any time. (See Programming Security Codes section.
Door Chime Feature The Door Chime feature provides a tone from the security station each time a monitored door or window is opened or closed. The zones which will activate the Door Chime must be programmed by your installer. The Door Chime only sounds while the system is in the disarmed state. If zones have been programmed to initiate the Door Chime, you may enable or disable the feature. Start with the panel in the disarmed mode, press [✱] to enter the function list, then scroll to find “User Functions”.
If an Alarm Sounds Keypad Zones Fire Alarm If your system has been installed with fire detectors and the alarm sounds in a pulsing mode, follow your emergency evacuation plan immediately. See guidelines for Family Escape Planning elsewhere in this manual. There are three keys on the keypad labelled [F] Fire, [A] Auxiliary and [P] Panic. These keys are only functional if they have been programmed by the installer.
If there is only one trouble condition, the display will show the [#] to exit message. If there are multiple troubles, the display will show each one as the scroll key is pressed. Press the [#] key to exit the trouble view mode. The trouble indicator (< >) will remain on the display until the trouble condition is cleared. Note: A TROUBLE condition reduces the security your system is designed to provide. Call your installing company for service.
Press [<] to see the previous function or item of information. Liquid Crystal Display (LCD) displays prompts and system information on two 16 character lines. If “< >” appears, it indicates that more information is available. Press either key to view. Press [>] to advance the display to next function or item of information. Press the [F] Key for 2 seconds to send a Fire transmission. Keypad Press keys as prompted by the LCD display to view alarms or troubles, to Arm/ Disarm the system or to shunt zones.