• W A R N I N G • This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. Instruction Manual TM Security Products © 1998 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29003372 R0 Software Version 2.
WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection.
About Your Security System Your DSC security equipment has been designed to provide you with the greatest possible flexibility and convenience. Read this manual carefully and have your installer instruct you on your system's operation and on which features have been implemented in your system. All users of this system should be equally instructed in its use. Fill out the “System Information” page with all of you zone information and access codes and store this manual in a safe place for future reference.
System Information Fill out the following information for future reference and store this manual in a safe place.
15 ___________________________________________ _____________________________________ 16 ___________________________________________ _____________________________________ 17 ___________________________________________ _____________________________________ 18 ___________________________________________ _____________________________________ 19 ___________________________________________ _____________________________________ 20 ___________________________________________ _______________________
Access Codes Access codes are used to arm and disarm the system. There are 37 access codes available: 1 master code, 32 regular access codes, 2 duress codes and 2 supervision codes. Ask your installer for more information on using the duress and supervision codes. Only the Master Code can be used to program additional security codes and to change other system features as well as to arm and disarm the security system. The Master Code will be supplied to you by your installer.
Alternate Arming Methods Away Arming Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion is detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will begin. To arm in the Away mode, enter your access code and exit the premises through a designated Exit/ Entry door. The system will recognise that occupants have left the premises. Once the exit delay expires, the system will be fully armed.
Quick Exit When the Quick Exit feature is enabled, pressing [✱][0] while the system is armed will provide a two minute window for you to exit the premises. During this time, you may only open and close the designated Entry/Exit door once. Once the door is closed, the panel will end the two minute quick exit delay. If the door is opened again, or if the door is not closed after two minutes, or if another zone is opened, the panel will begin the entry delay.
NOTE: If you return and find that an alarm has occurred while you were away, it is possible that an intruder may still be on the premises. Go to a neighbour's house, and call the local police to investigate. The alarm memory is cleared each time the panel is armed so that any alarms showing are alarms that occurred only during the last armed period.
PC1555RKZ LED Keypad Emergency Keys (All Keypads) PC5508Z LED Keypad LCD5500Z Keypad PC5508Z, PC5516Z, PC5532Z, LCD5500Z: Press both * Keys for two seconds to send a FIRE transmission. Press both * Keys for two seconds to send an AUXILIARY transmission. Press both * Keys for two seconds to send a PANIC transmission.
To erase a code: Enter [✱][5][Master Code][code number 01 to 32][✱]. Press [#] to return to the Ready state. The Master code cannot be erased. Programming codes from an LCD Keypad: Master Code Press the [✱] key to enter the function list. Scroll (< >) to... Press (*) for <> Press [5] or [✱]. The display will read... Access Codes Enter Master Access Code Enter your current Master Code. The display will read... (*) to Edit <> “40P” represents the Master Code.
Zone Bypassing The zone bypassing function is used when access is needed to part of the protected area while the system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made. Bypassed zones will not cause an alarm. Zones cannot be bypassed once the system is armed. Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied before the next arming.
To view troubles from an LED Keypad: A trouble will be indicated by the Trouble light (or System light on a PC1555RKZ keypad) which will remain ON until the trouble condition is cleared. If you cannot determine the cause of the trouble condition, contact your installer for assistance. To view the type of trouble condition, press [✱][2]. One or more zone lights will turn ON, indicating the various trouble conditions: ZONE LIGHT TYPE OF TROUBLE 1 ................. Service required.
Testing Your System Alarm Test The Alarm Test provides two second test of the keypad sounder and bell or siren. Begin with the panel in the Ready state. From an LED keypad, Enter [✱][6][Master Code][4] then press [#] to return to the Ready state. From an LCD keypad, press [✱] to enter the functions list. Use the arrow (< >) keys to scroll to find “User Functions” and press [✱] to select. Enter your Master Code and scroll to find the following message... Select Option <> Press [✱] to perform an Alarm Test.
To activate the door chime from an LCD Keypad: Press [✱] to enter the function list, then scroll to find... Press (*) For<> Press [✱] or [4] to enable or disable the Door Chime feature. Press [#] to return to the Ready state. Door Chime Keypad Options All Keypads Keypad Sounder Control The LCD keypad will allow you to select from 21 different keypad tones. From an LCD keypad, enter [✱][6][Master Code], then use the arrow keys (< >) to scroll to the message "Keypad Buzzer Control". Press [✱] to select.
To reset smoke detectors from an LCD Keypad: Press [✱] to enter the function list. Scroll to find: Press (*) For <> Press [✱] to select the output control. The display will read... Output Control Select Output <> Use the arrow (< >) keys to find the following message and press the [✱] key to Command Output #1 select... Select Output <> Command Output #2 NOTE: If you suspect that a fire alarm has transmitted and that there is no fire condition, call the monitoring station to avoid an unnecessary response.
• A good plan emphasizes quick escape. Do not investigate or attempt to fight the fire, and do not gather belongings or pets as this wastes valuable time. Once outside, do not re-enter the house. Wait for the fire department. • Write the fire escape plan down and rehearse it frequently so that should an emergency arise, everyone will know what to do. Revise the plan as conditions change, such as the number of people in the home, or if there are changes to the building's construction.
WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection.
• W A R N I N G • This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. Instruction Manual TM Security Products © 1998 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29003372 R0 Software Version 2.