Instructions / Assembly

Press the button under the
F
canopy (J), where the steel
wire comes out to adjust the
steel wires to the desired
length. Release the button to
hold the steel wire in position,
as shown in the diagram. Loosen
the plastic screw by using a
flathead screwdriver (not provided)
and adjust the fixture wire to the
desired length, then tighten the
plastic screw back into the hole as
shown in diagram.
Fasten the mounting strip (A)
Strip 2 cm / 3/4 in. of insulation from the wire ends. Twist the live wire from the fixture together with the black wire from outlet box.
Twist the neutral wire from the fixture together with the white wire from outlet box. Twist the bare copper ground wire from the canopy
together with the green ground wire from the fixture and the ground wire from the outlet box, the bare copper ground wire from the
canopy must loop one turn under the head of green ground screw (C) on the mounting strip (A) before it is connected to the ground
wire from the outlet box and the green ground wire from the fixture. Note: the live wire is labeled and marked “Black Live Wire/Câble
noir sous tension/Cable blanco neutral,” the neutral wire is labeled and marked “White Neutral Wire/Câble blanc neutre/Cable blanco
neutral.” The green ground wire from the
fixture is labeled and marked “Green Ground Wire/Câble vert de mise à la terre/Cable verde
The bare copper ground wire from the canopy is also labeled and marked “Bare Copper Ground Wire/Câble de cuivre de mise
à la terre/Cable de cobre desnudo a tierra.”
a tierra.”
onto the outlet box using 2
outlet box screws (D). Screw
the threaded tube (B) into
mounting strip (A). Using the
lock washer (E) and one hex
nut (F), secure the threaded
tube (B) in place. This threaded
tube (B) should extend long
enough to protrude through
the canopy when it is mounted.
(Adjust as needed)
Hang the end of the steel wires
to the hook of mounting strip (A)
as shown.
FIXTURE INSTALLATION
7900 N University Dr., Suite 202, Tamarac, FL 33321 USA
DSI Customer Service Hotline: 1-800-388-6141 ext 216 Mon. – Fri., 9:30 a.m. to 3:00 p.m. EST
Page 7 of 9
MADE IN CHINAMODEL : 16368
E
120V 60Hz
E
B
D
A
J
A
J
Outlet box/Boîte de sortie/Caja de salida
black
noir
white
blanc
ground
terre
Live Wire
Câble sous tension
Neutral Wire
Câble neutre
Green Ground Wire
Câble vert de mise
à la terre
Bare Copper Ground
Wire/Câble de cuivre
de mise à la terre
a tierra
negro
blanco
Cable de cobre a tierra
Cable verde a tierra
Cable vivo
Cable neutral