“Front Door Lock” in location 4 could appear as 4.0.1. This is a great help when 
calling for Tech Support. We know our numbers; we don’t know your names. Click 
on an individual input or output in Workstation and type xsd (DSX backwards). 
  Always follow the PC requirements page for Hardware and OS compatibility. The 
PC Requirements Page is in the WinDSX Tech Binder, Software Installation 
Manual, Price List, Catalog, and on the Website – www.dsxinc.com  
  There is a problem sharing an Access MDB database from a Vista PC to another 
Vista PC. If the shared DataBase is on a Windows 2000 or XP computer the 
database can be shared to a Vista PC. If the shared database is on the Vista PC is 
can be shared to PCs running 2000 or XP but not to another Vista PC. Microsoft 
issue that you must take up with Microsoft. Here is a link to the article on the Vista 
and Access issue.  http://support.microsoft.com/kb/935366 This has been 
taken care of in Vista Service Pack 1. 
  The displaying of the same event multiple times has typically been a problem with 
network routing and reflections. DSX has now implemented a filter that will prevent 
multiple lines of the same event from being displayed in Workstation. The issue is 
for example, when you see the same Access Granted event for the same person at 
the same door at the same time over and over. 
  127.0.0.1 is a default TCP/IP address that can be programmed into WinDSX if not 
connected to a network, or if on a network but no other PC’s are to run the 
workstation portion of WinDSX. 
 
For proper operation including printing of any sort from WinDSX, each 
Workstation PC must have a unique Workstation Name and Workstation #.
  Make sure a printer driver is loaded into the operating system. WinDSX software 
needs a printer driver installed before reports can be run. A printer is only needed if 
you want to print the reports to paper. 
  If the PC is not beeping on alarms, check the area Database>System 
Parameters>Workstation Name>Yes/No Options and “Enable Beep on Alarm”. 
Also, be sure Default Beep has been selected within the Operating System>Control 
Panel>Sounds. 
  The WinDSX Comm Server program, cs.exe, can be run as a service in Version 
3.7.34 and 4.8.6 and higher. The procedure and files necessary to do so are on the 
Software Installation CD in the Docs and Utilities folders. In older versions cs.exe 
can be placed into a startup folder. 